Objective: The aim of this retrospective, single-center study was to evaluate the occurrence of conduction disorders after rapid deployment aortic bioprosthesis implantation. Methods: Electrocardiograms of patients undergoing INTUITY (Edwards Lifesciences, Irvine, CA USA) bioprosthesis implantation were collected at admission, during postoperative course, and at discharge. Primary end point was the occurrence of new-onset conduction disorders, defined as complete left bundle branch block, complete right bundle branch block, permanent pacemaker implantation, and worsening of pre-existing rhythm abnormalities. Secondary end points were the assessment of preoperative and postoperative QRS duration and the identification of transitory conduction disorders. Results: Forty-four patients (July 2015–December 2016) were included in the analysis. Preoperatively, patients with normal conduction and with already existing disorders were 25 (56.8%) and 19 (43.2%), respectively. Primary end point occurred in 14 patients (31.8%). Two patients (4.5%) received pacemaker implantation. In patients with normal preoperative conduction, new abnormalities were found in eight cases (32%): all left bundle branch blocks with one pacemaker implantation. Worsening of pre-existing conduction disorders was found in six patients (31.6%) with one pacemaker implantation. QRS duration increased in 20 patients (45.4%), and average increase was 37 milliseconds. Overall, we observed a significant increase of QRS (96 ± 21 milliseconds vs. 111 ± 28 milliseconds, P < 0.001). Three patients experienced a new-onset temporary left bundle branch block. Conclusions: New-onset conduction disorders or worsening of pre-existing rhythm abnormalities occur in one third of patients after rapid deployment aortic bioprosthesis implantation. Although the incidence of postoperative pacemaker implantation before discharge is low, strict follow-up is mandatory to identify a potential need for pacemaker implantation in a timely manner.

D'Onofrio, A., Bagozzi, L., Tessari, C., Francescato, A., Cibin, G., Besola, L., et al. (2018). Evaluation of Conduction Disorders After Aortic Valve Replacement With Rapid Deployment Bioprostheses. INNOVATIONS, 13(5), 356-360 [10.1097/IMI.0000000000000558].

Evaluation of Conduction Disorders After Aortic Valve Replacement With Rapid Deployment Bioprostheses

D'Onofrio, A.;
2018-01-01

Abstract

Objective: The aim of this retrospective, single-center study was to evaluate the occurrence of conduction disorders after rapid deployment aortic bioprosthesis implantation. Methods: Electrocardiograms of patients undergoing INTUITY (Edwards Lifesciences, Irvine, CA USA) bioprosthesis implantation were collected at admission, during postoperative course, and at discharge. Primary end point was the occurrence of new-onset conduction disorders, defined as complete left bundle branch block, complete right bundle branch block, permanent pacemaker implantation, and worsening of pre-existing rhythm abnormalities. Secondary end points were the assessment of preoperative and postoperative QRS duration and the identification of transitory conduction disorders. Results: Forty-four patients (July 2015–December 2016) were included in the analysis. Preoperatively, patients with normal conduction and with already existing disorders were 25 (56.8%) and 19 (43.2%), respectively. Primary end point occurred in 14 patients (31.8%). Two patients (4.5%) received pacemaker implantation. In patients with normal preoperative conduction, new abnormalities were found in eight cases (32%): all left bundle branch blocks with one pacemaker implantation. Worsening of pre-existing conduction disorders was found in six patients (31.6%) with one pacemaker implantation. QRS duration increased in 20 patients (45.4%), and average increase was 37 milliseconds. Overall, we observed a significant increase of QRS (96 ± 21 milliseconds vs. 111 ± 28 milliseconds, P < 0.001). Three patients experienced a new-onset temporary left bundle branch block. Conclusions: New-onset conduction disorders or worsening of pre-existing rhythm abnormalities occur in one third of patients after rapid deployment aortic bioprosthesis implantation. Although the incidence of postoperative pacemaker implantation before discharge is low, strict follow-up is mandatory to identify a potential need for pacemaker implantation in a timely manner.
2018
Pubblicato
Rilevanza internazionale
Articolo
Comitato scientifico
Settore MED/23
Settore MEDS-13/C - Chirurgia cardiaca
English
Con Impact Factor ISI
Aortic valve replacement
Conduction disorder
Rapid deployment aortic prosthesis
Sutureless aortic prosthesis
D'Onofrio, A., Bagozzi, L., Tessari, C., Francescato, A., Cibin, G., Besola, L., et al. (2018). Evaluation of Conduction Disorders After Aortic Valve Replacement With Rapid Deployment Bioprostheses. INNOVATIONS, 13(5), 356-360 [10.1097/IMI.0000000000000558].
D'Onofrio, A; Bagozzi, L; Tessari, C; Francescato, A; Cibin, G; Besola, L; Pesce, R; Toscano, G; Gerosa, G
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
d-onofrio-et-al-2018-evaluation-of-conduction-disorders-after-aortic-valve-replacement-with-rapid-deployment.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 240.74 kB
Formato Adobe PDF
240.74 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/397044
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
social impact