We introduce a new parametrization for the parton distribution functions (PDFs) designed to be flexible in the small-x region. We implement it in the xFitter open-source PDF fitting tool, and compare it to the default xFitter parametrization, widely used for many PDF studies, and notably for the HERAPDF determination. We find that we can describe the combined inclusive HERA I+II data using NNLO theory with a significantly higher quality than HERAPDF2.0: the χ2 is reduced by more than 60 units, having used only four more parameters. Our result highlights a significant parametrization bias in the default xFitter parametrization at small x, which would lead to even more dramatic effects when used for higher-energy colliders, where the small-x region is more relevant. We also find that the inclusion of small-x resummation, that was shown in previous studies to lead to similar improvements in the fit quality, further reduces the χ2 by approximately 30 extra units.
Bonvini, M., Giuli, F. (2019). A new simple PDF parametrization: Improved description of the HERA data. THE EUROPEAN PHYSICAL JOURNAL PLUS, 134(10) [10.1140/epjp/i2019-12872-x].
A new simple PDF parametrization: Improved description of the HERA data
Giuli, Francesco
2019-01-01
Abstract
We introduce a new parametrization for the parton distribution functions (PDFs) designed to be flexible in the small-x region. We implement it in the xFitter open-source PDF fitting tool, and compare it to the default xFitter parametrization, widely used for many PDF studies, and notably for the HERAPDF determination. We find that we can describe the combined inclusive HERA I+II data using NNLO theory with a significantly higher quality than HERAPDF2.0: the χ2 is reduced by more than 60 units, having used only four more parameters. Our result highlights a significant parametrization bias in the default xFitter parametrization at small x, which would lead to even more dramatic effects when used for higher-energy colliders, where the small-x region is more relevant. We also find that the inclusion of small-x resummation, that was shown in previous studies to lead to similar improvements in the fit quality, further reduces the χ2 by approximately 30 extra units.| File | Dimensione | Formato | |
|---|---|---|---|
|
i2019-12872-x.pdf
solo utenti autorizzati
Tipologia:
Versione Editoriale (PDF)
Licenza:
Copyright dell'editore
Dimensione
3.38 MB
Formato
Adobe PDF
|
3.38 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


