Earth-based gravitational waves interferometric detectors are shot-noise limited in the high-frequency region of their sensitivity band. While enhancing the laser input power is the natural solution to improve on the shot noise limit, higher power also increases the optical aberration budget due to the laser absorption in the highly reflective coatings of mirrors, resulting in a drop of the sensitivity of the detector. Advanced Virgo exploits Hartmann Wavefront Sensors (HWSs) to locally measure the absorption-induced optical aberrations by monitoring the optical path length change in the core optics. Despite the very high sensitivity of Hartmann sensors, temperature fluctuations can cause a spurious curvature term to appear in the reconstructed wavefront due to the thermal expansion of the Hartmann plate, that could affect the accuracy of the aberration monitoring. We present the implementation and validation of a control loop to stabilize the Advanced Virgo HWS temperature at the order of Δ T ⩽ 0.01 K, keeping the spurious curvature within the detector’s requirements on wavefront sensing accuracy.

Aiello, L., Palma, P.p., Lorenzini, M., Cesarini, E., Cifaldi, M., Di Fronzo, C., et al. (2024). Thermal defocus-free Hartmann Wavefront Sensors for monitoring aberrations in Advanced Virgo. CLASSICAL AND QUANTUM GRAVITY, 41(12) [10.1088/1361-6382/ad4508].

Thermal defocus-free Hartmann Wavefront Sensors for monitoring aberrations in Advanced Virgo

Lorenzo Aiello
;
Pier Paolo Palma;Matteo Lorenzini;Maria Cifaldi;Diana Lumaca;Ilaria Nardecchia;Alessio Rocchi;Claudia Taranto;Viviana Fafone
2024-01-01

Abstract

Earth-based gravitational waves interferometric detectors are shot-noise limited in the high-frequency region of their sensitivity band. While enhancing the laser input power is the natural solution to improve on the shot noise limit, higher power also increases the optical aberration budget due to the laser absorption in the highly reflective coatings of mirrors, resulting in a drop of the sensitivity of the detector. Advanced Virgo exploits Hartmann Wavefront Sensors (HWSs) to locally measure the absorption-induced optical aberrations by monitoring the optical path length change in the core optics. Despite the very high sensitivity of Hartmann sensors, temperature fluctuations can cause a spurious curvature term to appear in the reconstructed wavefront due to the thermal expansion of the Hartmann plate, that could affect the accuracy of the aberration monitoring. We present the implementation and validation of a control loop to stabilize the Advanced Virgo HWS temperature at the order of Δ T ⩽ 0.01 K, keeping the spurious curvature within the detector’s requirements on wavefront sensing accuracy.
2024
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore PHYS-01/A - Fisica sperimentale delle interazioni fondamentali e applicazioni
English
Con Impact Factor ISI
Advanced Virgo
gravitational waves
ground-based interferometer
Hartmann Wavefront Sensor
optical aberrations
thermal defocus
Aiello, L., Palma, P.p., Lorenzini, M., Cesarini, E., Cifaldi, M., Di Fronzo, C., et al. (2024). Thermal defocus-free Hartmann Wavefront Sensors for monitoring aberrations in Advanced Virgo. CLASSICAL AND QUANTUM GRAVITY, 41(12) [10.1088/1361-6382/ad4508].
Aiello, L; Palma, Pp; Lorenzini, M; Cesarini, E; Cifaldi, M; Di Fronzo, C; Lumaca, D; Minenkov, Y; Nardecchia, I; Rocchi, A; Taranto, C; Fafone, V...espandi
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/392944
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact