BACKGROUND AND OBJECTIVES: This multicenter study aimed to assess the safety and efficacy of the Woven EndoBridge (WEB) device for treating unruptured wide-neck intracranial bifurcation aneurysms (WIBAs) with short-, mid-, and long-term follow-ups (FUPs). METHODS: Consecutive patients with unruptured WIBAs treated with WEB between December 2014 and January 2018 were included. Patient, aneurysm, and device characteristics were collected and analyzed retrospectively. Morbidity and mortality rates were determined by collecting intraprocedural, periprocedural, and delayed complications. Aneurysm occlusion was assessed at 1, 3, and 5 years using a 3-grade scale: complete occlusion, neck remnant, and residual aneurysm. Complete occlusion and neck remnant were considered as adequate occlusion. Patients who received re-treatment were also evaluated. RESULTS: The study included 104 consecutive patients (55.8% female, mean age 58.6 +/- 11.8 years). Aneurysm maximum size, neck, and dome-to-neck mean were, respectively, 6.9 +/- 2.1 mm, 4.5 +/- 1.2 mm, and 1.4 +/- 0.3 mm. One-year FUP was collected for 95 patients, and 3- and 5-year FUPs were collected for 83 patients. Adequate occlusion was observed at 1-year FUP in 90.5% (86/95), 91.6% (76/83) was observed at 3-year FUP, and 92.8% (77/83) at 5-year FUP. None of the aneurysms bled after treatment. During FUP, 6/83 patients (7.2%) were re-treated for residual aneurysm. Morbidity and mortality rates closely related to aneurysm occlusion were 0% (0/104). CONCLUSION: The WEB device was safe and effective for treating unruptured WIBAs, both in short-term and long-term FUPs.

Semeraro, V., Palmisano, V., Limbucci, N., Comelli, S., Comelli, C., Ganimede, M.p., et al. (2024). Woven EndoBridge Device for Unruptured Wide-Neck Bifurcation Aneurysm: A Multicenter 5-Year Follow-up. NEUROSURGERY, 94(5), 1044-1050 [10.1227/neu.0000000000002781].

Woven EndoBridge Device for Unruptured Wide-Neck Bifurcation Aneurysm: A Multicenter 5-Year Follow-up

Palmisano V.;Lozupone E.;Barone M.;Capasso F.;Gandini R.;Resta M.;
2024-01-01

Abstract

BACKGROUND AND OBJECTIVES: This multicenter study aimed to assess the safety and efficacy of the Woven EndoBridge (WEB) device for treating unruptured wide-neck intracranial bifurcation aneurysms (WIBAs) with short-, mid-, and long-term follow-ups (FUPs). METHODS: Consecutive patients with unruptured WIBAs treated with WEB between December 2014 and January 2018 were included. Patient, aneurysm, and device characteristics were collected and analyzed retrospectively. Morbidity and mortality rates were determined by collecting intraprocedural, periprocedural, and delayed complications. Aneurysm occlusion was assessed at 1, 3, and 5 years using a 3-grade scale: complete occlusion, neck remnant, and residual aneurysm. Complete occlusion and neck remnant were considered as adequate occlusion. Patients who received re-treatment were also evaluated. RESULTS: The study included 104 consecutive patients (55.8% female, mean age 58.6 +/- 11.8 years). Aneurysm maximum size, neck, and dome-to-neck mean were, respectively, 6.9 +/- 2.1 mm, 4.5 +/- 1.2 mm, and 1.4 +/- 0.3 mm. One-year FUP was collected for 95 patients, and 3- and 5-year FUPs were collected for 83 patients. Adequate occlusion was observed at 1-year FUP in 90.5% (86/95), 91.6% (76/83) was observed at 3-year FUP, and 92.8% (77/83) at 5-year FUP. None of the aneurysms bled after treatment. During FUP, 6/83 patients (7.2%) were re-treated for residual aneurysm. Morbidity and mortality rates closely related to aneurysm occlusion were 0% (0/104). CONCLUSION: The WEB device was safe and effective for treating unruptured WIBAs, both in short-term and long-term FUPs.
2024
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MEDS-22/A - Diagnostica per immagini e radioterapia
English
Unruptured intracranial aneurysm
WEB
Flow disruptor
Endovascular treatment
Semeraro, V., Palmisano, V., Limbucci, N., Comelli, S., Comelli, C., Ganimede, M.p., et al. (2024). Woven EndoBridge Device for Unruptured Wide-Neck Bifurcation Aneurysm: A Multicenter 5-Year Follow-up. NEUROSURGERY, 94(5), 1044-1050 [10.1227/neu.0000000000002781].
Semeraro, V; Palmisano, V; Limbucci, N; Comelli, S; Comelli, C; Ganimede, Mp; Lozupone, E; Barone, M; Marrazzo, A; Paladini, A; Della Malva, G; Briati...espandi
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/392113
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 2
social impact