Objective: This scoping review aimed to (1) critically evaluate the outcomes measures used to assess the accuracy of implant placement with Computer Assisted Implant Surgery (CAIS) and (2) review the evidence supporting the efficient implementation of CAIS in training and education of clinicians.Methods: A scoping literature review was conducted aiming to identify (a) clinical trials assessing accuracy of implant placement with CAIS, and (b) clinical trials or simulation/cadaver studies where CAIS was utilised and assessed for the training/education of clinicians. Studies since 1995 were assessed for suitability and data related to the outcomes measures of accuracy and educational efficacy were extracted and synthesised.Results: Accuracy of CAIS has been mainly assessed through surrogate measures. Individual clinical trials have not shown any difference between static and dynamic CAIS, but recent meta-analyses suggest an advantage of dynamic CAIS in reducing angular deviation. The combination of static and dynamic CAIS might offer higher accuracy than each of the two used alone. Dynamic CAIS is suitable for novice surgeons and might even have added value as an education tool for implant surgery, although mastering the technique requires longer training than static.Conclusion: Meta-analyses of large samples, new and diverse outcomes measures, as well as benchmarking of levels of accuracy with specific clinical outcomes will help to better understand the potential and limitations of CAIS. Dynamic CAIS is suitable for novice operators, but educational interventions distributed over longer periods of time will be required for mastery of the process.
Pimkhaokham, A., Chow, J., Pozzi, A., Arunjaroensuk, S., Subbalehka, K., Mattheos, N. (2024). Computer‐assisted and robotic implant surgery: Assessing the outcome measures of accuracy and educational implications. CLINICAL ORAL IMPLANTS RESEARCH, 35(8), 939-953 [10.1111/clr.14213].
Computer‐assisted and robotic implant surgery: Assessing the outcome measures of accuracy and educational implications
Pozzi, Alessandro;
2024-08-01
Abstract
Objective: This scoping review aimed to (1) critically evaluate the outcomes measures used to assess the accuracy of implant placement with Computer Assisted Implant Surgery (CAIS) and (2) review the evidence supporting the efficient implementation of CAIS in training and education of clinicians.Methods: A scoping literature review was conducted aiming to identify (a) clinical trials assessing accuracy of implant placement with CAIS, and (b) clinical trials or simulation/cadaver studies where CAIS was utilised and assessed for the training/education of clinicians. Studies since 1995 were assessed for suitability and data related to the outcomes measures of accuracy and educational efficacy were extracted and synthesised.Results: Accuracy of CAIS has been mainly assessed through surrogate measures. Individual clinical trials have not shown any difference between static and dynamic CAIS, but recent meta-analyses suggest an advantage of dynamic CAIS in reducing angular deviation. The combination of static and dynamic CAIS might offer higher accuracy than each of the two used alone. Dynamic CAIS is suitable for novice surgeons and might even have added value as an education tool for implant surgery, although mastering the technique requires longer training than static.Conclusion: Meta-analyses of large samples, new and diverse outcomes measures, as well as benchmarking of levels of accuracy with specific clinical outcomes will help to better understand the potential and limitations of CAIS. Dynamic CAIS is suitable for novice operators, but educational interventions distributed over longer periods of time will be required for mastery of the process.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.