purpose: to compare the clinical and radiological outcomes of two implant designs with different prosthetic interfaces and neck configurations. materials and methods: thirty-four partially edentate patients randomly received at least one nobelactive implant (nobel biocare, göteborg, sweden) with back-tapered collar, internal conical connection and platform shifting design, and one nobelSpeedy implant (nobel biocare) with external hexagon and flat-to-flat implant-abutment interface according to a split-mouth design. follow-up continued to 3 years post-loading. the primary outcome measures were the success rates of the implants and prostheses, and the occurrence of any surgical and prosthetic complications during the entire follow-up. secondary outcome measures were: horizontal and vertical peri-implant marginal bone level (MBL) changes, resonance frequency analysis values at implant placement and loading (4 months), sulcus bleeding index (SBI) and plaque score (PS). results: no drop-out occurred. no implants and prostheses failures were observed to the 3-year follow-up. MBL changes were statistically significant different with better results for the nobelactive implants for both horizontal and vertical measurements (P = 0.000). after 3 years post-loading, the nobelactive implants underwent a mean vertical bone resorption of 0.66 mm, compared with 1.25 mm for the nobelspeedy groovy implants (P = 0.000); the mean horizontal bone resorption was 0.19 mm for the NobelActive implants and 0.60 mm for the nobelspeedy groovy implants (P = 0.000). a high ISQ value was found for both implants, and no statistically significant difference was found for ISQ mean values between interventions (P = 0.941 at baseline; P = 0.454 at implantabutment connection; P = 0.120 at prosthesis delivery). all implants showed good periodontal health at the 3-year-in-function visit, with no significant differences between groups. conclusion: the results of this research suggest that in well-maintained patients, the MBL changes could be affected by the different implant design. after 4 months of unloaded healing, as well as after 3 years in function, both implants provided good results, however vertical and horizontal bone loss had statistically significant differences between the two groups (difference of 0.58 ± 0.10 mm for the vertical MBL, and 0.4 ± 0.05 mm for the horizontal MBL), with lower values in the nobel active implants, compared to the nobelSpeedy Groovy implants.

Pozzi, A., Tallarico, M., Moy, P. (2014). Three-year post-loading results of a randomised, controlled, split-mouth trial comparing implants with different prosthetic interfaces and design in partially posterior edentulous mandibles. EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 47-61.

Three-year post-loading results of a randomised, controlled, split-mouth trial comparing implants with different prosthetic interfaces and design in partially posterior edentulous mandibles

Pozzi A
;
2014-01-01

Abstract

purpose: to compare the clinical and radiological outcomes of two implant designs with different prosthetic interfaces and neck configurations. materials and methods: thirty-four partially edentate patients randomly received at least one nobelactive implant (nobel biocare, göteborg, sweden) with back-tapered collar, internal conical connection and platform shifting design, and one nobelSpeedy implant (nobel biocare) with external hexagon and flat-to-flat implant-abutment interface according to a split-mouth design. follow-up continued to 3 years post-loading. the primary outcome measures were the success rates of the implants and prostheses, and the occurrence of any surgical and prosthetic complications during the entire follow-up. secondary outcome measures were: horizontal and vertical peri-implant marginal bone level (MBL) changes, resonance frequency analysis values at implant placement and loading (4 months), sulcus bleeding index (SBI) and plaque score (PS). results: no drop-out occurred. no implants and prostheses failures were observed to the 3-year follow-up. MBL changes were statistically significant different with better results for the nobelactive implants for both horizontal and vertical measurements (P = 0.000). after 3 years post-loading, the nobelactive implants underwent a mean vertical bone resorption of 0.66 mm, compared with 1.25 mm for the nobelspeedy groovy implants (P = 0.000); the mean horizontal bone resorption was 0.19 mm for the NobelActive implants and 0.60 mm for the nobelspeedy groovy implants (P = 0.000). a high ISQ value was found for both implants, and no statistically significant difference was found for ISQ mean values between interventions (P = 0.941 at baseline; P = 0.454 at implantabutment connection; P = 0.120 at prosthesis delivery). all implants showed good periodontal health at the 3-year-in-function visit, with no significant differences between groups. conclusion: the results of this research suggest that in well-maintained patients, the MBL changes could be affected by the different implant design. after 4 months of unloaded healing, as well as after 3 years in function, both implants provided good results, however vertical and horizontal bone loss had statistically significant differences between the two groups (difference of 0.58 ± 0.10 mm for the vertical MBL, and 0.4 ± 0.05 mm for the horizontal MBL), with lower values in the nobel active implants, compared to the nobelSpeedy Groovy implants.
2014
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MEDS-16/A - Malattie odontostomatologiche
English
Con Impact Factor ISI
Pozzi, A., Tallarico, M., Moy, P. (2014). Three-year post-loading results of a randomised, controlled, split-mouth trial comparing implants with different prosthetic interfaces and design in partially posterior edentulous mandibles. EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 47-61.
Pozzi, A; Tallarico, M; Moy, P
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
Eur J Oral Implantol 2014 Pozzi.pdf

non disponibili

Tipologia: Versione Editoriale (PDF)
Licenza: Non specificato
Dimensione 557.96 kB
Formato Adobe PDF
557.96 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/391176
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 69
  • ???jsp.display-item.citation.isi??? 67
social impact