the purpose of this study is to retrospectively evaluate the implant and prosthetic survival and success rates of zirconia-based, implant-supported, screw-retained, cross-arch restorations up to 5 years after placement. materials and methods twenty-two consecutive edentulous patients (11 males and females, each; mean age 68.3 years) received 26 CAD/CAM cross-arch zirconia implant bridges (nobelprocera™ Implant Bridge zirconia; nobel biocare AG, zurich, switzerland) supported by 4 to 10 implants each. all patients were followed for at least 3 years (range 36–60 months, mean 42.3 months). clinical assessments were scheduled every 4 months during hygiene maintenance. outcomes were implant and prosthetic survival rates, prosthetic success rate, any observed clinical complications, patient satisfaction, and soft tissue parameters. fisher's exact test was used to assess associations between categorical variables. results no dropouts occurred. the overall implant and prostheses survival rate up to 5 years was 100%. three out of 26 restorations (five out of three hundred forty eight dental units) showed an adhesive chip-off fracture of the veneering ceramic, scoring a cumulative prosthetic success rate of 88.5% at the prosthetic level and 98.6% at the unit level. all 22 patients were functionally and aesthetically highly satisfied with their restorations. successful soft tissue parameters were found around all implants. conclusions industrially manufactured, zirconia-based, implant-supported, screw-retained, cross-arch restorations are a viable alternative to conventionally manufactured porcelain-fused-to-metal restorations for rehabilitating the edentulous patient.

Pozzi, A., Holst, S., Fabbri, G., Tallarico, M. (2015). Clinical reliability of CAD/CAM cross-arch zirconia bridges on immediately loaded implants placed with computer-assisted/template-guided surgery: a retrospective study with a follow-up between 3 and 5 years. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH [10.1111/cid.12132].

Clinical reliability of CAD/CAM cross-arch zirconia bridges on immediately loaded implants placed with computer-assisted/template-guided surgery: a retrospective study with a follow-up between 3 and 5 years

Pozzi A
;
2015-01-01

Abstract

the purpose of this study is to retrospectively evaluate the implant and prosthetic survival and success rates of zirconia-based, implant-supported, screw-retained, cross-arch restorations up to 5 years after placement. materials and methods twenty-two consecutive edentulous patients (11 males and females, each; mean age 68.3 years) received 26 CAD/CAM cross-arch zirconia implant bridges (nobelprocera™ Implant Bridge zirconia; nobel biocare AG, zurich, switzerland) supported by 4 to 10 implants each. all patients were followed for at least 3 years (range 36–60 months, mean 42.3 months). clinical assessments were scheduled every 4 months during hygiene maintenance. outcomes were implant and prosthetic survival rates, prosthetic success rate, any observed clinical complications, patient satisfaction, and soft tissue parameters. fisher's exact test was used to assess associations between categorical variables. results no dropouts occurred. the overall implant and prostheses survival rate up to 5 years was 100%. three out of 26 restorations (five out of three hundred forty eight dental units) showed an adhesive chip-off fracture of the veneering ceramic, scoring a cumulative prosthetic success rate of 88.5% at the prosthetic level and 98.6% at the unit level. all 22 patients were functionally and aesthetically highly satisfied with their restorations. successful soft tissue parameters were found around all implants. conclusions industrially manufactured, zirconia-based, implant-supported, screw-retained, cross-arch restorations are a viable alternative to conventionally manufactured porcelain-fused-to-metal restorations for rehabilitating the edentulous patient.
2015
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MEDS-16/A - Malattie odontostomatologiche
English
Con Impact Factor ISI
Pozzi, A., Holst, S., Fabbri, G., Tallarico, M. (2015). Clinical reliability of CAD/CAM cross-arch zirconia bridges on immediately loaded implants placed with computer-assisted/template-guided surgery: a retrospective study with a follow-up between 3 and 5 years. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH [10.1111/cid.12132].
Pozzi, A; Holst, S; Fabbri, G; Tallarico, M
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
Clin Implant Dent Relat Res 2015 Pozzi-1.pdf

non disponibili

Tipologia: Versione Editoriale (PDF)
Licenza: Non specificato
Dimensione 390.35 kB
Formato Adobe PDF
390.35 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/391167
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 64
social impact