This paper presents an outdoor performance monitoring method for degradation studies of perovskite modules, focusing on a large-area perovskite module (81.9 cm2) over a long-term monitoring campaign. The module underwent an industrial lamination process to prevent long-term degradation from environmental factors. The characterization procedure involved degradation correction and determining the temperature coefficients and electrical parameters of the module using initial days of measurements. The results demonstrated temperature coefficients for Isc, Voc, and Pm (α′, β′, and γ) of −0.071%·K−1, −0.119%·K−1, and −0.113%·K−1, respectively, indicating a minimal temperature influence on this technology compared with conventional ones. Using this coefficient, the STC electrical parameters were retrieved from 1-min power output data, resolving the uncertainty of the indoor/outdoor IV curve measurements caused by the curve scan direction (JV hysteresis effect). We also highlight the initial remarkable capacity recovery effect of almost 16% during the first 2 days of operation. Additionally, a procedure that includes the IV curves analysis taken every 10 min and their translation to standard conditions has been implemented to evaluate the degradation of the module over the long-term outdoor campaign. The results show three different trends over the period.
Bovesecchi, G., Petitta, M., Pierro, M., Agresti, A., Pescetelli, S., Leonardi, E., et al. (2024). Outdoor performance monitoring method for degradation studies of perovskite modules. PROGRESS IN PHOTOVOLTAICS [10.1002/pip.3860].
Outdoor performance monitoring method for degradation studies of perovskite modules
Bovesecchi, Gianluigi
;Petitta, Marcello;Pierro, Marco;Agresti, Antonio;Pescetelli, Sara;Di Carlo, Aldo;Cornaro, Cristina
2024-01-01
Abstract
This paper presents an outdoor performance monitoring method for degradation studies of perovskite modules, focusing on a large-area perovskite module (81.9 cm2) over a long-term monitoring campaign. The module underwent an industrial lamination process to prevent long-term degradation from environmental factors. The characterization procedure involved degradation correction and determining the temperature coefficients and electrical parameters of the module using initial days of measurements. The results demonstrated temperature coefficients for Isc, Voc, and Pm (α′, β′, and γ) of −0.071%·K−1, −0.119%·K−1, and −0.113%·K−1, respectively, indicating a minimal temperature influence on this technology compared with conventional ones. Using this coefficient, the STC electrical parameters were retrieved from 1-min power output data, resolving the uncertainty of the indoor/outdoor IV curve measurements caused by the curve scan direction (JV hysteresis effect). We also highlight the initial remarkable capacity recovery effect of almost 16% during the first 2 days of operation. Additionally, a procedure that includes the IV curves analysis taken every 10 min and their translation to standard conditions has been implemented to evaluate the degradation of the module over the long-term outdoor campaign. The results show three different trends over the period.File | Dimensione | Formato | |
---|---|---|---|
Progress in Photovoltaics - 2024 - Bovesecchi - Outdoor Performance Monitoring Method for Degradation Studies of Perovskite.pdf
solo utenti autorizzati
Tipologia:
Versione Editoriale (PDF)
Licenza:
Copyright dell'editore
Dimensione
4.34 MB
Formato
Adobe PDF
|
4.34 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.