aims: we aimed to evaluate lesson learnt from a pilot project in mozambique focused on point-of-care (POC) HbA1c testing for diabetes management in primary health care facilities. methods: over a three-year period, several health centers were equipped with POC HbA1c testing machines. the evaluation involved 12 months of data collection, interviews with patients and staff, and regular supervision visits. results: the project screened over 22,000 individuals and provided HbA1c testing to 2362 diabetes patients. among the analyzed results, 65.7 % had HbA1c levels below 7 %, 10.9 % between 7 % and 8.5 %, and 23.4 % above 8.5 %. POC testing showed advantages such as reduced costs and improved workload management. conclusions: limited access to HbA1c testing remains a challenge in african countries. the pilot project demonstrated the feasibility of POC HbA1c testing and highlighted the need for increased efforts to make it more widely available, leading to improved diabetes management and patient outcomes.

Ciccacci, F., Ismael, F., Parruque, F., Júlio Maquete, D., Loureiro, S., Balamala, M., et al. (2024). Implementing HbA1c monitoring in sub-Saharan Africa: Lessons learnt from a pilot project in Mozambique. PUBLIC HEALTH IN PRACTICE, 7 [10.1016/j.puhip.2024.100504].

Implementing HbA1c monitoring in sub-Saharan Africa: Lessons learnt from a pilot project in Mozambique

Fausto Ciccacci;Stefano Orlando;
2024-01-01

Abstract

aims: we aimed to evaluate lesson learnt from a pilot project in mozambique focused on point-of-care (POC) HbA1c testing for diabetes management in primary health care facilities. methods: over a three-year period, several health centers were equipped with POC HbA1c testing machines. the evaluation involved 12 months of data collection, interviews with patients and staff, and regular supervision visits. results: the project screened over 22,000 individuals and provided HbA1c testing to 2362 diabetes patients. among the analyzed results, 65.7 % had HbA1c levels below 7 %, 10.9 % between 7 % and 8.5 %, and 23.4 % above 8.5 %. POC testing showed advantages such as reduced costs and improved workload management. conclusions: limited access to HbA1c testing remains a challenge in african countries. the pilot project demonstrated the feasibility of POC HbA1c testing and highlighted the need for increased efforts to make it more widely available, leading to improved diabetes management and patient outcomes.
2024
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MEDS-24/B - Igiene generale e applicata
English
Ciccacci, F., Ismael, F., Parruque, F., Júlio Maquete, D., Loureiro, S., Balamala, M., et al. (2024). Implementing HbA1c monitoring in sub-Saharan Africa: Lessons learnt from a pilot project in Mozambique. PUBLIC HEALTH IN PRACTICE, 7 [10.1016/j.puhip.2024.100504].
Ciccacci, F; Ismael, F; Parruque, F; Júlio Maquete, D; Loureiro, S; Balamala, M; Morviducci, L; Manto, A; Lanti, F; Orlando, S; Guidotti, G...espandi
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
Ciccacci 2024 - Implementing HbA1c monitoring in sub-Saharan Africa- Lessons learnt from a pilot project in Mozambique.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 320.67 kB
Formato Adobe PDF
320.67 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/388776
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact