Feedhorn- and orthomode transducer- (OMT) coupled transition edge sensor (TES) bolometers have been designed and micro-fabricated to meet the optical specifications of the LiteBIRD high frequency telescope (HFT) focal plane. We discuss the design and optical characterization of two LiteBIRD HFT detector types: dual-polarization, dual-frequency-band pixels with 195/280 GHz and 235/337 GHz band centers. Results show well-matched passbands between orthogonal polarization channels and frequency centers within 3% of the design values. The optical efficiency of each frequency channel is conservatively reported to be within the range 0.64-0.72, determined from the response to a cryogenic, temperature-controlled thermal source. These values are in good agreement with expectations and either exceed or are within 10% of the values used in the LiteBIRD sensitivity forecast. Lastly, we report a measurement of loss in Nb/SiN x/Nb microstrip at 100 mK and over the frequency range 200-350 GHz, which is comparable to values previously reported in the literature.

Hubmayr, J., Ade, P., Adler, A., Allys, E., Alonso, D., Arnold, K., et al. (2022). Optical Characterization of OMT-Coupled TES Bolometers for LiteBIRD. JOURNAL OF LOW TEMPERATURE PHYSICS, 209(3-4), 396-408 [10.1007/s10909-022-02808-7].

Optical Characterization of OMT-Coupled TES Bolometers for LiteBIRD

Carones, A.;Migliaccio, M.;Ritacco, A.;Vittorio, N.;
2022-01-01

Abstract

Feedhorn- and orthomode transducer- (OMT) coupled transition edge sensor (TES) bolometers have been designed and micro-fabricated to meet the optical specifications of the LiteBIRD high frequency telescope (HFT) focal plane. We discuss the design and optical characterization of two LiteBIRD HFT detector types: dual-polarization, dual-frequency-band pixels with 195/280 GHz and 235/337 GHz band centers. Results show well-matched passbands between orthogonal polarization channels and frequency centers within 3% of the design values. The optical efficiency of each frequency channel is conservatively reported to be within the range 0.64-0.72, determined from the response to a cryogenic, temperature-controlled thermal source. These values are in good agreement with expectations and either exceed or are within 10% of the values used in the LiteBIRD sensitivity forecast. Lastly, we report a measurement of loss in Nb/SiN x/Nb microstrip at 100 mK and over the frequency range 200-350 GHz, which is comparable to values previously reported in the literature.
2022
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore FIS/05
English
Con Impact Factor ISI
CMB
TES
OMT
Low temperature detector
Bolometer
Hubmayr, J., Ade, P., Adler, A., Allys, E., Alonso, D., Arnold, K., et al. (2022). Optical Characterization of OMT-Coupled TES Bolometers for LiteBIRD. JOURNAL OF LOW TEMPERATURE PHYSICS, 209(3-4), 396-408 [10.1007/s10909-022-02808-7].
Hubmayr, J; Ade, Par; Adler, A; Allys, E; Alonso, D; Arnold, K; Auguste, D; Aumont, J; Aurlien, R; Austermann, Je; Azzoni, S; Baccigalupi, C; Banday, ...espandi
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/365366
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 2
social impact