purpose to compare brain magnetic resonance imaging (MRI) using T1 3D silent and fast T1 3D gradient-echo (GRE) BRAin volume (known as BRAVO) sequences. the primary aim is to assess the quantitative and qualitative analysis of silent and BRAVO images by the measurement of the contrast (C), the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR). The second aim is to estimate the subjective sound levels and the specific absorption rate (SAR). methods twenty-two subjects had T1 3D silent and T1 3D BRAVO sequences added to the standard MR examination. the qualitative analysis of the two sequences was performed by two radiologists independently. the quantitative analysis was performed by placing regions of interest on the cerebrospinal fluid, on the white and grey matter. the C, the CNR and the SNR were calculated for each sequence. after each T1-3D sequence, subjects gave a score rating to evaluate the acoustic noise. finally, the SAR was evaluated by the digital imaging and communications in medicine (DICOM) tags. results the image quality scores obtained by the two radiologists were higher for BRAVO compared to the Silent. However, qualitatively, the silent images were similar to BRAVO for diagnostic use. quantitatively, CNR for GM-CSF was comparable in the two sequences and SNR in CSF was higher in Silent than BRAVO. the acoustic noise of silent sequence was statistically lower compared with BRAVO. the maximum SAR measured was 1.4 W/kg. conclusions 3D T1 silent can be a valid alternative technique to conventional BRAVO to reduce the acoustic noise preserving the diagnostic accuracy. however, radiologists preferred the conventional sequence to Silent.

Di Giuliano, F., Minosse, S., Picchi, E., Ferrazzoli, V., Da Ros, V., Muto, M., et al. (2021). qualitative and quantitative analysis of 3D T1 silent imaging. LA RADIOLOGIA MEDICA, 126(9), 1207-1215 [10.1007/s11547-021-01380-6].

qualitative and quantitative analysis of 3D T1 silent imaging

Di Giuliano, F.;Minosse, S.
;
Picchi, E.;Ferrazzoli, V.;Da Ros, V.;Muto, M.;Pistolese, C. A.;Garaci, F.;Floris, R.
2021-01-01

Abstract

purpose to compare brain magnetic resonance imaging (MRI) using T1 3D silent and fast T1 3D gradient-echo (GRE) BRAin volume (known as BRAVO) sequences. the primary aim is to assess the quantitative and qualitative analysis of silent and BRAVO images by the measurement of the contrast (C), the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR). The second aim is to estimate the subjective sound levels and the specific absorption rate (SAR). methods twenty-two subjects had T1 3D silent and T1 3D BRAVO sequences added to the standard MR examination. the qualitative analysis of the two sequences was performed by two radiologists independently. the quantitative analysis was performed by placing regions of interest on the cerebrospinal fluid, on the white and grey matter. the C, the CNR and the SNR were calculated for each sequence. after each T1-3D sequence, subjects gave a score rating to evaluate the acoustic noise. finally, the SAR was evaluated by the digital imaging and communications in medicine (DICOM) tags. results the image quality scores obtained by the two radiologists were higher for BRAVO compared to the Silent. However, qualitatively, the silent images were similar to BRAVO for diagnostic use. quantitatively, CNR for GM-CSF was comparable in the two sequences and SNR in CSF was higher in Silent than BRAVO. the acoustic noise of silent sequence was statistically lower compared with BRAVO. the maximum SAR measured was 1.4 W/kg. conclusions 3D T1 silent can be a valid alternative technique to conventional BRAVO to reduce the acoustic noise preserving the diagnostic accuracy. however, radiologists preferred the conventional sequence to Silent.
2021
Pubblicato
Rilevanza internazionale
Articolo
Sì, ma tipo non specificato
Settore MED/37 - Neuroradiologia
English
Acoustic noise
Magnetic resonance imaging
Neuroimaging
Silent scan
Di Giuliano, F., Minosse, S., Picchi, E., Ferrazzoli, V., Da Ros, V., Muto, M., et al. (2021). qualitative and quantitative analysis of 3D T1 silent imaging. LA RADIOLOGIA MEDICA, 126(9), 1207-1215 [10.1007/s11547-021-01380-6].
Di Giuliano, F; Minosse, S; Picchi, E; Ferrazzoli, V; Da Ros, V; Muto, M; Pistolese, Ca; Garaci, F; Floris, R
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
01_DiGiuliano2021_RadiologicaMedica.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 1.73 MB
Formato Adobe PDF
1.73 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/360323
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
social impact