this prospective single-cohort study aimed to evaluate the clinical and radiological performance of a novel dental implant positioned in post-extraction sockets in the anterior zone of both jaws and immediately loaded after 1 year in function. MATERIALS AND METHODS: patients requiring single implant in the anterior zone were treated between january and march 2019 and followed for at least 1 year of function. minimum values of 35 Ncm or 64 ISQ were required to perform immediate loading. Screw-retained zirconia-based single prostheses were delivered after the healing period. patients were followed up for 1 year after definitive prosthesis placement to determine implant and prosthetic survival rate, marginal bone loss (MBL), insertion torque, and ISQ values.RESULTS: 40 implants (bonelevel X, straumann AG) were positioned in 60 patients. none of the positioned implants failed accounting for an implant survival rate of 100 %. no definitive prostheses failed to result in a 100% prosthetic success rate. mean MBL was 0.6 mm ± 0.4 mm. mean overall insertion torque was 58.9 ± 13.8 while mean overall ISQ at implant placement was 72.3 ± 8.1.CONCLUSION: Within the limitations of the present prospective single-cohort study, the investigated clinical and radiological performance of the novel dental implant placed in the anterior zone seems to be a reliable treatment option.

Carosi, P., Cardelli, P., Laureti, A., Leggeri, A., Lorenzi, C. (2022). immediate single implant placement and loading in the aesthetic zone with a novel dental implant: a 1-year prospective single cohort study.

immediate single implant placement and loading in the aesthetic zone with a novel dental implant: a 1-year prospective single cohort study

Carosi P.;Cardelli P.;Laureti A.;
2022-01-01

Abstract

this prospective single-cohort study aimed to evaluate the clinical and radiological performance of a novel dental implant positioned in post-extraction sockets in the anterior zone of both jaws and immediately loaded after 1 year in function. MATERIALS AND METHODS: patients requiring single implant in the anterior zone were treated between january and march 2019 and followed for at least 1 year of function. minimum values of 35 Ncm or 64 ISQ were required to perform immediate loading. Screw-retained zirconia-based single prostheses were delivered after the healing period. patients were followed up for 1 year after definitive prosthesis placement to determine implant and prosthetic survival rate, marginal bone loss (MBL), insertion torque, and ISQ values.RESULTS: 40 implants (bonelevel X, straumann AG) were positioned in 60 patients. none of the positioned implants failed accounting for an implant survival rate of 100 %. no definitive prostheses failed to result in a 100% prosthetic success rate. mean MBL was 0.6 mm ± 0.4 mm. mean overall insertion torque was 58.9 ± 13.8 while mean overall ISQ at implant placement was 72.3 ± 8.1.CONCLUSION: Within the limitations of the present prospective single-cohort study, the investigated clinical and radiological performance of the novel dental implant placed in the anterior zone seems to be a reliable treatment option.
2022
Pubblicato
Rilevanza internazionale
Articolo
Comitato scientifico
Settore MED/06
English
dental implant, dental teratment
Carosi, P., Cardelli, P., Laureti, A., Leggeri, A., Lorenzi, C. (2022). immediate single implant placement and loading in the aesthetic zone with a novel dental implant: a 1-year prospective single cohort study.
Carosi, P; Cardelli, P; Laureti, A; Leggeri, A; Lorenzi, C
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/357943
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact