Cogeneration (CHP) and Heat Pump (HP) are playing a key role in energy systems due to their high efficiency, especially, in energy refurbishment of buildings and industrial processes. This paper explored the opportunity to couple those two well-established technologies for heating purposes. Basically, the coupling entails limitations and constraints consisting of the mismatch between the power sizes of merchandised machines as well as the deriving technical issues. The main aim of this paper is to analyse the coupling procedure to help HVAC specialists in their job. This paper deals with a simple model formulation, based on the First Law of thermodynamics, for CHP/HP systems rating and off-design operations. Indeed, an analytical method was designed along with the definition of a size factor. Then, a graphical method for coupling CHP and HP was presented so as to be an expeditious tool in designing phase. Finally, two numerical applications were illustrated highlighting the energy performance gains and the high level of operation flexibility.

LO BASSO, G., Nastasi, B., Salata, F., Golasi, I. (2017). Energy retrofitting of residential buildings - How to couple Combined Heat and Power (CHP) and Heat Pump (HP) for thermal management and off-design operation. ENERGY AND BUILDINGS, 151, 293-305 [10.1016/j.enbuild.2017.06.060].

Energy retrofitting of residential buildings - How to couple Combined Heat and Power (CHP) and Heat Pump (HP) for thermal management and off-design operation

NASTASI, BENEDETTO
;
2017-01-01

Abstract

Cogeneration (CHP) and Heat Pump (HP) are playing a key role in energy systems due to their high efficiency, especially, in energy refurbishment of buildings and industrial processes. This paper explored the opportunity to couple those two well-established technologies for heating purposes. Basically, the coupling entails limitations and constraints consisting of the mismatch between the power sizes of merchandised machines as well as the deriving technical issues. The main aim of this paper is to analyse the coupling procedure to help HVAC specialists in their job. This paper deals with a simple model formulation, based on the First Law of thermodynamics, for CHP/HP systems rating and off-design operations. Indeed, an analytical method was designed along with the definition of a size factor. Then, a graphical method for coupling CHP and HP was presented so as to be an expeditious tool in designing phase. Finally, two numerical applications were illustrated highlighting the energy performance gains and the high level of operation flexibility.
2017
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore ING-IND/11
English
Con Impact Factor ISI
building and industrial applications
CHP
coupling energy systems
energy efficiency
heat pumps
civil and structural engineering
building and construction
mechanical engineering
electrical and electronic engineering
http://www.sciencedirect.com/science/article/pii/S0378778817306722
LO BASSO, G., Nastasi, B., Salata, F., Golasi, I. (2017). Energy retrofitting of residential buildings - How to couple Combined Heat and Power (CHP) and Heat Pump (HP) for thermal management and off-design operation. ENERGY AND BUILDINGS, 151, 293-305 [10.1016/j.enbuild.2017.06.060].
LO BASSO, G; Nastasi, B; Salata, F; Golasi, I
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
LoBasso_Energy retrofitting_2017.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 4 MB
Formato Adobe PDF
4 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/356383
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 47
  • ???jsp.display-item.citation.isi??? 40
social impact