purpose: to evaluate a novel deep learning algorithm to distinguish between eyes that may or may not have a graft detachment based on pre-descemet membrane endothelial keratoplasty (DMEK) anterior segment optical coherence tomography (AS-OCT) images. methods: retrospective cohort study. a multiple-instance learning artificial intelligence (MIL-AI) model using a resnet-101 backbone was designed. AS-OCT images were split into training and testing sets. The MIL-AI model was trained and validated on the training set. model performance and heatmaps were calculated from the testing set. classification performance metrics included F1 score (harmonic mean of recall and precision), specificity, sensitivity, and area under curve (AUC). Finally, MIL-AI perfor-mance was compared to manual classification by an experienced ophthalmologist. results: In total, 9466 images of 74 eyes (128 images per eye) were included in the study. Images from 50 eyes were used to train and validate the MIL-AI system, while the remaining 24 eyes were used as the test set to determine its performance and gener-ate heatmaps for visualization. the performance metrics on the test set (95% confidence interval) were as follows: F1 score, 0.77 (0.57-0.91); precision, 0.67 (0.44-0.88); specificity, 0.45 (0.15-0.75); sensitivity, 0.92 (0.73-1.00); and AUC, 0.63 (0.52-0.86). MIL-AI perfor-mance was more sensitive (92% vs. 31%) but less specific (45% vs. 64%) than the ophthal-mologist's performance. conclusions: The MIL-AI predicts with high sensitivity the eyes that may have post-DMEK graft detachment requiring rebubbling. Larger-scale clinical trials are warranted to validate the model. translational relevance: MIL-AI models represent an opportunity for implementation in routine DMEK suitability screening.
Patefield, A., Meng, Y., Airaldi, M., Coco, G., Vaccaro, S., Parekh, M., et al. (2023). Deep Learning Using Preoperative AS-OCT Predicts Graft Detachment in DMEK. TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 12(5), 14 [10.1167/tvst.12.5.14].
Deep Learning Using Preoperative AS-OCT Predicts Graft Detachment in DMEK
Coco, Giulia;
2023-05-01
Abstract
purpose: to evaluate a novel deep learning algorithm to distinguish between eyes that may or may not have a graft detachment based on pre-descemet membrane endothelial keratoplasty (DMEK) anterior segment optical coherence tomography (AS-OCT) images. methods: retrospective cohort study. a multiple-instance learning artificial intelligence (MIL-AI) model using a resnet-101 backbone was designed. AS-OCT images were split into training and testing sets. The MIL-AI model was trained and validated on the training set. model performance and heatmaps were calculated from the testing set. classification performance metrics included F1 score (harmonic mean of recall and precision), specificity, sensitivity, and area under curve (AUC). Finally, MIL-AI perfor-mance was compared to manual classification by an experienced ophthalmologist. results: In total, 9466 images of 74 eyes (128 images per eye) were included in the study. Images from 50 eyes were used to train and validate the MIL-AI system, while the remaining 24 eyes were used as the test set to determine its performance and gener-ate heatmaps for visualization. the performance metrics on the test set (95% confidence interval) were as follows: F1 score, 0.77 (0.57-0.91); precision, 0.67 (0.44-0.88); specificity, 0.45 (0.15-0.75); sensitivity, 0.92 (0.73-1.00); and AUC, 0.63 (0.52-0.86). MIL-AI perfor-mance was more sensitive (92% vs. 31%) but less specific (45% vs. 64%) than the ophthal-mologist's performance. conclusions: The MIL-AI predicts with high sensitivity the eyes that may have post-DMEK graft detachment requiring rebubbling. Larger-scale clinical trials are warranted to validate the model. translational relevance: MIL-AI models represent an opportunity for implementation in routine DMEK suitability screening.File | Dimensione | Formato | |
---|---|---|---|
2023. DeepLearningUsingPreoperative AS-OCTPredicts Graft DetachmentinDMEK.pdf
accesso aperto
Tipologia:
Versione Editoriale (PDF)
Licenza:
Creative commons
Dimensione
1.19 MB
Formato
Adobe PDF
|
1.19 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.