We are developing a prototype of cryogenic parametric converter transducer operating at 5 GHz, for the upgrade of the ROG Collaboration resonant G. W. antennas. This device is built on the experience of the Niobe detector (D. G. Blair et al.), with substantial modifications that should let us achieve better stability and sensitivity. The prototype uses as parametric converter a superconducting coaxial cavity with a 50 micron gap (Q 0 = 5 × 10 8 at 1.5K and 100μW RF power dissipation), and a contacless RF coupling for thermal insulation between the 2K stage and the ultra cryogenic (100mK) antenna. The coupler features a constant transmission loss of 0.2dB over a range of displacements of 5mm in x, y and z around the nominal operating position with a separation of 8mm between the two halves of the coupler. In this way the large, low frequency swings (0.5 and 17 Hz), of the 2 Tons antenna around its suspension point have no influence on the transducer performance. To test all the components of the transducer and the system performance, a room temperature prototype is installed on the TART (Test Antenna at Room Temperature) facility at the INFN labs. Using critical coupling for the RF cavity input coupler we manage to keep to a minimum the leakage of the drive signal to the first RF amplifier. In this way we avoid degradation of the RF amplifier noise figure (0.6 dB at room temperature) produced by the RF amplifier saturation Experimental results agree with the full analysis of the room temperature detector performances. © 2008 IOP Publishing Ltd.

Bassan, M., Ballantini, R., Chincarini, A., Gemme, G., Iannuzzi, M., Moleti, A., et al. (2008). New parametric transducer for resonant detectors: Advances and room temperature test. JOURNAL OF PHYSICS. CONFERENCE SERIES, 122, 0120311-0120316 [10.1088/1742-6596/122/1/012031].

New parametric transducer for resonant detectors: Advances and room temperature test

BASSAN, MASSIMO;MOLETI, ARTURO;
2008-01-01

Abstract

We are developing a prototype of cryogenic parametric converter transducer operating at 5 GHz, for the upgrade of the ROG Collaboration resonant G. W. antennas. This device is built on the experience of the Niobe detector (D. G. Blair et al.), with substantial modifications that should let us achieve better stability and sensitivity. The prototype uses as parametric converter a superconducting coaxial cavity with a 50 micron gap (Q 0 = 5 × 10 8 at 1.5K and 100μW RF power dissipation), and a contacless RF coupling for thermal insulation between the 2K stage and the ultra cryogenic (100mK) antenna. The coupler features a constant transmission loss of 0.2dB over a range of displacements of 5mm in x, y and z around the nominal operating position with a separation of 8mm between the two halves of the coupler. In this way the large, low frequency swings (0.5 and 17 Hz), of the 2 Tons antenna around its suspension point have no influence on the transducer performance. To test all the components of the transducer and the system performance, a room temperature prototype is installed on the TART (Test Antenna at Room Temperature) facility at the INFN labs. Using critical coupling for the RF cavity input coupler we manage to keep to a minimum the leakage of the drive signal to the first RF amplifier. In this way we avoid degradation of the RF amplifier noise figure (0.6 dB at room temperature) produced by the RF amplifier saturation Experimental results agree with the full analysis of the room temperature detector performances. © 2008 IOP Publishing Ltd.
2008
Pubblicato
Rilevanza internazionale
Articolo
Sì, ma tipo non specificato
Settore FIS/01 - FISICA SPERIMENTALE
English
onde gravitazionali,trasduttore, microonde
Bassan, M., Ballantini, R., Chincarini, A., Gemme, G., Iannuzzi, M., Moleti, A., et al. (2008). New parametric transducer for resonant detectors: Advances and room temperature test. JOURNAL OF PHYSICS. CONFERENCE SERIES, 122, 0120311-0120316 [10.1088/1742-6596/122/1/012031].
Bassan, M; Ballantini, R; Chincarini, A; Gemme, G; Iannuzzi, M; Moleti, A; Parodi, Rf; Vaccarone, R
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

Questo articolo è pubblicato sotto una Licenza Licenza Creative Commons Creative Commons

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/34097
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? ND
social impact