A fast-neutron detector for time-resolved beam measurements at spallation neutron sources is presented. The device features a p -type/intrinsic/metal Schottky barrier structure where the active (intrinsic) detection layer is a 150 μm thick single-crystal diamond obtained by chemical-vapour deposition. Coupling to fast front-end electronics preserves the excellent timing properties of the device as demonstrated in tests performed at the ISIS spallation neutron source in UK. The device represents a novel approach in the field of pulsed fast-neutrons spectroscopic techniques. It will find immediate application in localized (mm resolution) fast-neutron fluence measurements required by neutron irradiation experiments at ISIS also envisaging its use for spectrum measurements.

Pietropaolo, A., Andreani, C., Rebai, M., Giacomelli, L., Gorini, G., Cippo, E., et al. (2010). Single-crystal diamond detector for time-resolved measurements of a pulsed fast-neutron beam. EUROPHYSICS LETTERS, 92(6), 68003 (6 pp.)-68003 (6 pp.) - [10.1209/0295-5075/92/68003].

Single-crystal diamond detector for time-resolved measurements of a pulsed fast-neutron beam

PIETROPAOLO, ANTONINO;ANDREANI, CARLA;GIACOMELLI, LUIGI;VERONA RINATI, GIANLUCA;Verona, C;MARINELLI, MARCO;MILANI, ENRICO;
2010-12-01

Abstract

A fast-neutron detector for time-resolved beam measurements at spallation neutron sources is presented. The device features a p -type/intrinsic/metal Schottky barrier structure where the active (intrinsic) detection layer is a 150 μm thick single-crystal diamond obtained by chemical-vapour deposition. Coupling to fast front-end electronics preserves the excellent timing properties of the device as demonstrated in tests performed at the ISIS spallation neutron source in UK. The device represents a novel approach in the field of pulsed fast-neutrons spectroscopic techniques. It will find immediate application in localized (mm resolution) fast-neutron fluence measurements required by neutron irradiation experiments at ISIS also envisaging its use for spectrum measurements.
dic-2010
Pubblicato
Rilevanza internazionale
Articolo
Sì, ma tipo non specificato
Settore FIS/01 - FISICA SPERIMENTALE
English
chemical vapour deposition;neutron effects;neutron sources;nuclear spallation;Schottky barriers;time of flight spectrometers;time resolved spectroscopy;
Pietropaolo, A., Andreani, C., Rebai, M., Giacomelli, L., Gorini, G., Cippo, E., et al. (2010). Single-crystal diamond detector for time-resolved measurements of a pulsed fast-neutron beam. EUROPHYSICS LETTERS, 92(6), 68003 (6 pp.)-68003 (6 pp.) - [10.1209/0295-5075/92/68003].
Pietropaolo, A; Andreani, C; Rebai, M; Giacomelli, L; Gorini, G; Cippo, E; Tardocchi, M; Fazzi, A; VERONA RINATI, G; Verona, C; Marinelli, M; Milani, ...espandi
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/33727
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 41
  • ???jsp.display-item.citation.isi??? 37
social impact