Background: Since 2010, the Ovation Abdominal Stent Graft System has offered an innovative sealing option for abdominal aortic aneurysm (AAA) by including a sealing ring filled with polymer 13 mm from the renal arteries. In August 2020, the redesigned Ovation Alto, with a sealing ring 6 mm closer to the top of the fabric, received CE Mark approval.Objective: This registry study aims to evaluate intraoperative, perioperative, and postoperative results in patients treated by the Alto stent graft (Endologix Inc.) for elective AAA repair in a multicentric consecutive experience.Methods: All consecutive eligible patients submitted to endovascular aneurysm repair (EVAR) by Alto Endovascular AAA implantation will be included in this analysis. Patients will be submitted to EVAR procedures based on their own preferences, anatomical features, and operators experience. An estimated number of 300 patients submitted to EVAR with Alto stent graft should be enrolled. It is estimated that the inclusion period will be 24 months. The follow-up period is set to be 5 years. Full data sets and cross-sectional images of contrast-enhanced computed tomography scan performed before EVAR, at the first postoperative month, at 24 or 36 months, and at 5-year follow-up interval will be reported in the central database for a centralized core laboratory review of morphological changes. The primary endpoint of the study is to evaluate the technical and clinical success of EVAR with the Alto stent graft in short- (90-thy), mid- (1-year), and long-term (5-year) follow-up periods. The following secondary endpoints will be also addressed: operative time; intraoperative radiation exposure; contrast medium usage; AAA sac shrinkage at 12-month and 5-year follow-up; any potential role of patients' baseline characteristics, valuated on preoperative computed tomography angiographic study, and of device configuration (number of component) in the primary endpoint.Results: The study is currently in the recruitment phase and the final patient is expected to be treated by the end of 2023 and then followed up for 5 years. A total of 300 patients will be recruited. Analyses will focus on primary and secondary endpoints. Updated results will be shared at 1- and 3-5-year follow-ups.Conclusions: The results from this registry study could validate the safety and effectiveness of the new design of the Ovation Alto Stent Graft. The technical modifications to the endograft could allow for accommodation of a more comprehensive range of anatomies on-label.
Gianmarco, D.d., Edoardo, P., Pasqualino, S., Francesco, T., Giancarlo, P., Maurizio, T., et al. (2022). Endovascular Abdominal Aortic Aneurysm Repair With Ovation Alto Stent Graft: Protocol for the ALTAIR (ALTo endogrAft Italian Registry) Study. JMIR RESEARCH PROTOCOLS, 11(7) [10.2196/36995].
Endovascular Abdominal Aortic Aneurysm Repair With Ovation Alto Stent Graft: Protocol for the ALTAIR (ALTo endogrAft Italian Registry) Study
Arnaldo, Ippoliti;Stefano, Fazzini;Fabio Massimo, Oddi;Matteo, Barbante;Paola, Orlando;
2022-07-11
Abstract
Background: Since 2010, the Ovation Abdominal Stent Graft System has offered an innovative sealing option for abdominal aortic aneurysm (AAA) by including a sealing ring filled with polymer 13 mm from the renal arteries. In August 2020, the redesigned Ovation Alto, with a sealing ring 6 mm closer to the top of the fabric, received CE Mark approval.Objective: This registry study aims to evaluate intraoperative, perioperative, and postoperative results in patients treated by the Alto stent graft (Endologix Inc.) for elective AAA repair in a multicentric consecutive experience.Methods: All consecutive eligible patients submitted to endovascular aneurysm repair (EVAR) by Alto Endovascular AAA implantation will be included in this analysis. Patients will be submitted to EVAR procedures based on their own preferences, anatomical features, and operators experience. An estimated number of 300 patients submitted to EVAR with Alto stent graft should be enrolled. It is estimated that the inclusion period will be 24 months. The follow-up period is set to be 5 years. Full data sets and cross-sectional images of contrast-enhanced computed tomography scan performed before EVAR, at the first postoperative month, at 24 or 36 months, and at 5-year follow-up interval will be reported in the central database for a centralized core laboratory review of morphological changes. The primary endpoint of the study is to evaluate the technical and clinical success of EVAR with the Alto stent graft in short- (90-thy), mid- (1-year), and long-term (5-year) follow-up periods. The following secondary endpoints will be also addressed: operative time; intraoperative radiation exposure; contrast medium usage; AAA sac shrinkage at 12-month and 5-year follow-up; any potential role of patients' baseline characteristics, valuated on preoperative computed tomography angiographic study, and of device configuration (number of component) in the primary endpoint.Results: The study is currently in the recruitment phase and the final patient is expected to be treated by the end of 2023 and then followed up for 5 years. A total of 300 patients will be recruited. Analyses will focus on primary and secondary endpoints. Updated results will be shared at 1- and 3-5-year follow-ups.Conclusions: The results from this registry study could validate the safety and effectiveness of the new design of the Ovation Alto Stent Graft. The technical modifications to the endograft could allow for accommodation of a more comprehensive range of anatomies on-label.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.