Deep Inelastic Neutron Scattering ( DINS) measurements have been performed on a liquid water sample at two different temperatures and pressures. The experiments were carried out using the VESUVIO spectrometer at the ISIS spallation neutron source. This experiment represents the first DINS measurement from water using the Resonance Detector configuration, employing yttrium-aluminum-perovskite scintillator and a U-238 analyzer foil. The maximum energy of the scattered neutrons was about 70 eV, allowing to access an extended kinematic space with energy and wave vector transfers at the proton recoil peak in the range 1 eV <= h omega <= 20 eV and 25 angstrom(-1) <= q <= 90 angstrom(-1), respectively. Comparison with DINS measurements on water performed in the standard Resonance Filter configuration indicates the potential advantages offered by the use of Resonance Detector approach for DINS measurements at forward scattering angles.
Pietropaolo, A., Andreani, C., Filabozzi, A., Senesi, R., Gorini, G., Perelli Cippo, E., et al. (2006). DINS measurements on VESUVIO in the Resonance Detector configuration: Proton mean kinetic energy in water. JOURNAL OF INSTRUMENTATION, 1(1), 1-25 [http://dx.doi.org/10.1088/1748-0221/1/04/P04001].
DINS measurements on VESUVIO in the Resonance Detector configuration: Proton mean kinetic energy in water
PIETROPAOLO, ANTONINO;ANDREANI, CARLA;FILABOZZI, ALESSANDRA;SENESI, ROBERTO;
2006-01-01
Abstract
Deep Inelastic Neutron Scattering ( DINS) measurements have been performed on a liquid water sample at two different temperatures and pressures. The experiments were carried out using the VESUVIO spectrometer at the ISIS spallation neutron source. This experiment represents the first DINS measurement from water using the Resonance Detector configuration, employing yttrium-aluminum-perovskite scintillator and a U-238 analyzer foil. The maximum energy of the scattered neutrons was about 70 eV, allowing to access an extended kinematic space with energy and wave vector transfers at the proton recoil peak in the range 1 eV <= h omega <= 20 eV and 25 angstrom(-1) <= q <= 90 angstrom(-1), respectively. Comparison with DINS measurements on water performed in the standard Resonance Filter configuration indicates the potential advantages offered by the use of Resonance Detector approach for DINS measurements at forward scattering angles.File | Dimensione | Formato | |
---|---|---|---|
93 copy.pdf
accesso aperto
Descrizione: MAIN ARTICLE
Dimensione
910.35 kB
Formato
Adobe PDF
|
910.35 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.