Despite females being more often affected by asthma than males and the prevalence of COPD rising in females, conflicting evidence exists as to whether sex may modulate the correct inhaler technique. The aim of this study was to assess the impact of sex on the proper use of inhaler devices in asthma and COPD. A pairwise meta-analysis was performed on studies enrolling adult males and females with asthma or COPD and reporting data of patients making at least one error by inhaler device type (DPI, MDI, and SMI). The data of 6,571 patients with asthma or COPD were extracted from 12 studies. A moderate quality of evidence (GRADE +++) indicated that sex may influence the correct use of inhaler device in both asthma and COPD. The critical error rate was higher in females with asthma (OR 1.31, 95%CI 1.14-1.50) and COPD (OR 1.80, 95%CI 1.22-2.67) using DPI vs. males (p < 0.01). In addition, the use of SMI in COPD was associated with a greater rate of critical errors in females vs. males (OR 5.36, 95%CI 1.48-19.32; p < 0.05). No significant difference resulted for MDI. In conclusion, choosing the right inhaler device in agreement with sex may optimize the pharmacological treatment of asthma and COPD.

Calzetta, L., Aiello, M., Frizzelli, A., Ritondo, B.l., Pistocchini, E., Rogliani, P., et al. (2022). Impact of Sex on Proper Use of Inhaler Devices in Asthma and COPD: A Systematic Review and Meta-Analysis. PHARMACEUTICS, 14(8), 1565 [10.3390/pharmaceutics14081565].

Impact of Sex on Proper Use of Inhaler Devices in Asthma and COPD: A Systematic Review and Meta-Analysis

Calzetta, Luigino;Rogliani, Paola;
2022-07-28

Abstract

Despite females being more often affected by asthma than males and the prevalence of COPD rising in females, conflicting evidence exists as to whether sex may modulate the correct inhaler technique. The aim of this study was to assess the impact of sex on the proper use of inhaler devices in asthma and COPD. A pairwise meta-analysis was performed on studies enrolling adult males and females with asthma or COPD and reporting data of patients making at least one error by inhaler device type (DPI, MDI, and SMI). The data of 6,571 patients with asthma or COPD were extracted from 12 studies. A moderate quality of evidence (GRADE +++) indicated that sex may influence the correct use of inhaler device in both asthma and COPD. The critical error rate was higher in females with asthma (OR 1.31, 95%CI 1.14-1.50) and COPD (OR 1.80, 95%CI 1.22-2.67) using DPI vs. males (p < 0.01). In addition, the use of SMI in COPD was associated with a greater rate of critical errors in females vs. males (OR 5.36, 95%CI 1.48-19.32; p < 0.05). No significant difference resulted for MDI. In conclusion, choosing the right inhaler device in agreement with sex may optimize the pharmacological treatment of asthma and COPD.
28-lug-2022
Pubblicato
Rilevanza internazionale
Recensione
Esperti anonimi
Settore MED/10 - MALATTIE DELL'APPARATO RESPIRATORIO
English
Con Impact Factor ISI
COPD
asthma
inhaler device
inhaler technique
meta-analysis
sex
Calzetta, L., Aiello, M., Frizzelli, A., Ritondo, B.l., Pistocchini, E., Rogliani, P., et al. (2022). Impact of Sex on Proper Use of Inhaler Devices in Asthma and COPD: A Systematic Review and Meta-Analysis. PHARMACEUTICS, 14(8), 1565 [10.3390/pharmaceutics14081565].
Calzetta, L; Aiello, M; Frizzelli, A; Ritondo, Bl; Pistocchini, E; Rogliani, P; Chetta, A
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
pharmaceutics-14-01565.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 1.96 MB
Formato Adobe PDF
1.96 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/330863
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 3
social impact