: After the discovery of the hazardous effects of xylene, less toxic substitutes were proposed for routine histology in the last years. However, the introduction of new xylene-free substitutes in histological processes requires a careful evaluation of their performance in terms of morphological and microscopic details to permit a solid diagnosis as well as good quality immunohistochemical and biomolecular analyses. In this study, we analyzed the performance of a new commercially available xylene-free Tissue-Tek® Tissue-Clear® agent in comparison with another routine xylene-free solvent yet available and employed in routine histological process. Serial histological tissue samples (n = 300) were selected and processed with the two clearing agents. Comparison and evaluation were also performed on slides obtained 6 months after paraffin embedding and archive storage. Blinded semiquantitative analysis of technical performance and morphological details, including tissue architecture and nuclear and cytoplasmic details, was performed on Haematoxylin-Eosin stained sections by two technicians and two pathologists, respectively. Evaluation of tissue slides documented a good overall histological performance in slides obtained after processing with the two different clearing agents. Slides obtained with Tissue-Tek® Tissue-Clear® displayed a higher score in some quality parameters, further supporting its use as a valid alternative to the other commercial routine xylene-free solvents.
Scioli, M.g., Fabbri, G., Cappelli, S., Savino, L., Ferlosio, A., Orlandi, A. (2023). A high-performance xylene-free tissue-clearing agent for routine histology: Preliminary histomorphological results. ANNALS OF DIAGNOSTIC PATHOLOGY, 66, 152163 [10.1016/j.anndiagpath.2023.152163].
A high-performance xylene-free tissue-clearing agent for routine histology: Preliminary histomorphological results
Cappelli, Sabrina;Ferlosio, Amedeo;Orlandi, Augusto
2023-05-15
Abstract
: After the discovery of the hazardous effects of xylene, less toxic substitutes were proposed for routine histology in the last years. However, the introduction of new xylene-free substitutes in histological processes requires a careful evaluation of their performance in terms of morphological and microscopic details to permit a solid diagnosis as well as good quality immunohistochemical and biomolecular analyses. In this study, we analyzed the performance of a new commercially available xylene-free Tissue-Tek® Tissue-Clear® agent in comparison with another routine xylene-free solvent yet available and employed in routine histological process. Serial histological tissue samples (n = 300) were selected and processed with the two clearing agents. Comparison and evaluation were also performed on slides obtained 6 months after paraffin embedding and archive storage. Blinded semiquantitative analysis of technical performance and morphological details, including tissue architecture and nuclear and cytoplasmic details, was performed on Haematoxylin-Eosin stained sections by two technicians and two pathologists, respectively. Evaluation of tissue slides documented a good overall histological performance in slides obtained after processing with the two different clearing agents. Slides obtained with Tissue-Tek® Tissue-Clear® displayed a higher score in some quality parameters, further supporting its use as a valid alternative to the other commercial routine xylene-free solvents.File | Dimensione | Formato | |
---|---|---|---|
scioli 2023.pdf
solo utenti autorizzati
Tipologia:
Versione Editoriale (PDF)
Licenza:
Copyright dell'editore
Dimensione
283.73 kB
Formato
Adobe PDF
|
283.73 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.