Mitigation or even elimination of adverse effects caused by ionizing radiation is the main scope of the radiation protection discipline. The interaction of radiation with living matter is quantified and correlated with biological effects by dose. The Sievert is the most well-known quantity, and it is used with the equivalent and effective dose to minimize stochastic effects. However, Gray is the reference quantity for sizing tissue reactions that could occur under high-exposure conditions such as in a radiation emergency. The topics addressed in this review are the choice to move from Sievert to Gray, how the operational quantities for environmental and individual monitoring of the detectors should consider such a change of units, and why reference levels substitute dose levels in emergency exposure.

Ferrari, C., Manenti, G., Malizia, A. (2023). Sievert or Gray: Dose Quantities and Protection Levels in Emergency Exposure. SENSORS, 23(4), 1-10 [10.3390/s23041918].

Sievert or Gray: Dose Quantities and Protection Levels in Emergency Exposure

Manenti G.;Malizia A.
2023-02-01

Abstract

Mitigation or even elimination of adverse effects caused by ionizing radiation is the main scope of the radiation protection discipline. The interaction of radiation with living matter is quantified and correlated with biological effects by dose. The Sievert is the most well-known quantity, and it is used with the equivalent and effective dose to minimize stochastic effects. However, Gray is the reference quantity for sizing tissue reactions that could occur under high-exposure conditions such as in a radiation emergency. The topics addressed in this review are the choice to move from Sievert to Gray, how the operational quantities for environmental and individual monitoring of the detectors should consider such a change of units, and why reference levels substitute dose levels in emergency exposure.
feb-2023
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MED/36 - DIAGNOSTICA PER IMMAGINI E RADIOTERAPIA
English
Con Impact Factor ISI
dose quantities
dose reference levels
radiation emergency
Ferrari, C., Manenti, G., Malizia, A. (2023). Sievert or Gray: Dose Quantities and Protection Levels in Emergency Exposure. SENSORS, 23(4), 1-10 [10.3390/s23041918].
Ferrari, C; Manenti, G; Malizia, A
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
sensors-23-01918-v2 (1).pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 499.39 kB
Formato Adobe PDF
499.39 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/323833
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact