The superiority of transcatheter (TAVR) over surgical aortic valve replacement (SAVR) for severe aortic stenosis (AS) has not been fully demonstrated in a real-world setting. This prospective study included 5706 AS patients who underwent SAVR from 2010 to 2012 and 2989 AS patients who underwent TAVR from 2017 to 2018 from the prospective multicenter observational studies OBSERVANT I and II. Early adverse events as well as all-cause mortality, major adverse cardiac and cerebrovascular events (MACCEs), and hospital readmission due to heart failure at 1-year were investigated. Among 1008 propensity score matched pairs, TAVR was associated with significantly lower 30-day mortality (1.8 vs. 3.5%, p = 0.020), stroke (0.8 vs. 2.3%, p = 0.005), and acute kidney injury (0.6 vs. 8.2%, p < 0.001) compared to SAVR. Moderate-to-severe paravalvular regurgitation (5.9 vs. 2.0%, p < 0.001) and permanent pacemaker implantation (13.8 vs. 3.3%, p < 0.001) were more frequent after TAVR. At 1-year, TAVR was associated with lower risk of all-cause mortality (7.9 vs. 11.5%, p = 0.006), MACCE (12.0 vs. 15.8%, p = 0.011), readmission due to heart failure (10.8 vs. 15.9%, p < 0.001), and stroke (3.2 vs. 5.1%, p = 0.033) compared to SAVR. TAVR reduced 1-year mortality in the subgroups of patients aged 80 years or older (HR 0.49, 95% CI 0.33-0.71), in females (HR 0.57, 0.38-0.85), and among patients with EuroSCORE II >= 4.0% (HR 0.48, 95% CI 0.32-0.71). In a real-world setting, TAVR using new-generation devices was associated with lower rates of adverse events up to 1-year follow-up compared to SAVR.

Rosato, S., Biancari, F., D'Errigo, P., Barbanti, M., Tarantini, G., Bedogni, F., et al. (2021). One-Year Outcomes after Surgical versus Transcatheter Aortic Valve Replacement with Newer Generation Devices. JOURNAL OF CLINICAL MEDICINE, 10(16), 1-13 [10.3390/jcm10163703].

One-Year Outcomes after Surgical versus Transcatheter Aortic Valve Replacement with Newer Generation Devices

Ussia, Gian Paolo;Ruvolo, Giovanni;Nardi, Paolo;Pisano, Calogera
2021-08-20

Abstract

The superiority of transcatheter (TAVR) over surgical aortic valve replacement (SAVR) for severe aortic stenosis (AS) has not been fully demonstrated in a real-world setting. This prospective study included 5706 AS patients who underwent SAVR from 2010 to 2012 and 2989 AS patients who underwent TAVR from 2017 to 2018 from the prospective multicenter observational studies OBSERVANT I and II. Early adverse events as well as all-cause mortality, major adverse cardiac and cerebrovascular events (MACCEs), and hospital readmission due to heart failure at 1-year were investigated. Among 1008 propensity score matched pairs, TAVR was associated with significantly lower 30-day mortality (1.8 vs. 3.5%, p = 0.020), stroke (0.8 vs. 2.3%, p = 0.005), and acute kidney injury (0.6 vs. 8.2%, p < 0.001) compared to SAVR. Moderate-to-severe paravalvular regurgitation (5.9 vs. 2.0%, p < 0.001) and permanent pacemaker implantation (13.8 vs. 3.3%, p < 0.001) were more frequent after TAVR. At 1-year, TAVR was associated with lower risk of all-cause mortality (7.9 vs. 11.5%, p = 0.006), MACCE (12.0 vs. 15.8%, p = 0.011), readmission due to heart failure (10.8 vs. 15.9%, p < 0.001), and stroke (3.2 vs. 5.1%, p = 0.033) compared to SAVR. TAVR reduced 1-year mortality in the subgroups of patients aged 80 years or older (HR 0.49, 95% CI 0.33-0.71), in females (HR 0.57, 0.38-0.85), and among patients with EuroSCORE II >= 4.0% (HR 0.48, 95% CI 0.32-0.71). In a real-world setting, TAVR using new-generation devices was associated with lower rates of adverse events up to 1-year follow-up compared to SAVR.
20-ago-2021
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MED/23 - CHIRURGIA CARDIACA
English
aortic valve replacement
transcatheter aortic valve implantation (TAVI)
transcatheter aortic valve replacement (TAVR)
Rosato, S., Biancari, F., D'Errigo, P., Barbanti, M., Tarantini, G., Bedogni, F., et al. (2021). One-Year Outcomes after Surgical versus Transcatheter Aortic Valve Replacement with Newer Generation Devices. JOURNAL OF CLINICAL MEDICINE, 10(16), 1-13 [10.3390/jcm10163703].
Rosato, S; Biancari, F; D'Errigo, P; Barbanti, M; Tarantini, G; Bedogni, F; Ranucci, M; Costa, G; Juvonen, T; Ussia, Gp; Marcellusi, A; Baglio, G; Cicala, Sd; Badoni, G; Seccareccia, F; Tamburino, C; On Behalf Of The Observant Ii Research, G; In, A; Ruvolo, G; Nardi, P; Pisano, C
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
Observant 2.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 1.21 MB
Formato Adobe PDF
1.21 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/313628
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
social impact