Although machine perfusion (MP) is being increasingly adopted in liver transplantation, indications, timing, and modality are debated. To investigate current indications for MP a web-based Google Forms survey was launched in January 2021 and addressed to 127 experts in the field, identified among first and corresponding Authors of MP literature in the last 10 years. The survey presented 10 real-life cases of donor-recipient matching, asking whether the liver would be accepted (Q1), whether MP would be used in that particular setting (Q2) and, if so, by which MP modality (Q3) and at what timing during preservation (Q4). Respondents could also comment on each case. The agreement was evaluated using Krippendorff's alpha coefficient. Answers from 39 (30.1%) participants disclosed significant heterogeneity in graft acceptance, MP indications, technique, and timing. Agreement between respondents was generally poor (Q1, α = 0.11; Q2, α = 0.14; Q3, α = 0.12, Q4, α = 0.11). Overall, respondents preferred hypothermic MP and an end-ischemic approach in 56.3% and 81.1% of cases, respectively. A total of 18 (46.2%) participants considered only one MP approach, whereas 17 (43.6%) and 3 (7.7%) considered using alternatively 2 or 3 different techniques. Of 38 comments, 17 (44.7%) were about the use of MP for graft viability assessment before implantation. This survey shows considerable variability in MP indications, emphasizing the need to identify scenarios of optimal utilization for each technique. Viability assessment emerges as a fundamental need of transplant professionals when considering the use of MP.

Patrono, D., Cussa, D., Rigo, F., Romagnoli, R., Angelico, R., Bellini, M.i., et al. (2022). Heterogeneous indications and the need for viability assessment: An international survey on the use of machine perfusion in liver transplantation. ARTIFICIAL ORGANS, 46(2), 296-305 [10.1111/aor.14061].

Heterogeneous indications and the need for viability assessment: An international survey on the use of machine perfusion in liver transplantation

Angelico R.;Bellini M. I.;Manzia T. M.;Pagano D.;
2022-01-01

Abstract

Although machine perfusion (MP) is being increasingly adopted in liver transplantation, indications, timing, and modality are debated. To investigate current indications for MP a web-based Google Forms survey was launched in January 2021 and addressed to 127 experts in the field, identified among first and corresponding Authors of MP literature in the last 10 years. The survey presented 10 real-life cases of donor-recipient matching, asking whether the liver would be accepted (Q1), whether MP would be used in that particular setting (Q2) and, if so, by which MP modality (Q3) and at what timing during preservation (Q4). Respondents could also comment on each case. The agreement was evaluated using Krippendorff's alpha coefficient. Answers from 39 (30.1%) participants disclosed significant heterogeneity in graft acceptance, MP indications, technique, and timing. Agreement between respondents was generally poor (Q1, α = 0.11; Q2, α = 0.14; Q3, α = 0.12, Q4, α = 0.11). Overall, respondents preferred hypothermic MP and an end-ischemic approach in 56.3% and 81.1% of cases, respectively. A total of 18 (46.2%) participants considered only one MP approach, whereas 17 (43.6%) and 3 (7.7%) considered using alternatively 2 or 3 different techniques. Of 38 comments, 17 (44.7%) were about the use of MP for graft viability assessment before implantation. This survey shows considerable variability in MP indications, emphasizing the need to identify scenarios of optimal utilization for each technique. Viability assessment emerges as a fundamental need of transplant professionals when considering the use of MP.
2022
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MED/18 - CHIRURGIA GENERALE
English
ex situ organ perfusion
machine perfusion
normothermic regional perfusion
organ preservation
viability assessment
Patrono, D., Cussa, D., Rigo, F., Romagnoli, R., Angelico, R., Bellini, M.i., et al. (2022). Heterogeneous indications and the need for viability assessment: An international survey on the use of machine perfusion in liver transplantation. ARTIFICIAL ORGANS, 46(2), 296-305 [10.1111/aor.14061].
Patrono, D; Cussa, D; Rigo, F; Romagnoli, R; Angelico, R; Bellini, Mi; Bonaccorsi-Riani, E; Bruggenwirth, Ima; Czigany, Z; De Carlis, R; De Meijer, Ve...espandi
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/313491
Citazioni
  • ???jsp.display-item.citation.pmc??? 11
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 13
social impact