The ability to monitor protein biomarkers continuously and in real-time would significantly advance the precision of medicine. Current protein-detection techniques, however, including ELISA and lateral flow assays, provide only time-delayed, single-time-point measurements, limiting their ability to guide prompt responses to rapidly evolving, life-threatening conditions. In response, here we present an electrochemical aptamer-based sensor (EAB) that supports high-frequency, real-time biomarker measurements. Specifically, we have developed an electrochemical, aptamer-based (EAB) sensor against Neutrophil Gelatinase-Associated Lipocalin (NGAL), a protein that, if present in urine at levels above a threshold value, is indicative of acute renal/kidney injury (AKI). When deployed inside a urinary catheter, the resulting reagentless, wash-free sensor supports real-time, high-frequency monitoring of clinically relevant NGAL concentrations over the course of hours. By providing an “early warning system”, the ability to measure levels of diagnostically relevant proteins such as NGAL in real-time could fundamentally change how we detect, monitor, and treat many important diseases.

Parolo, C., Idili, A., Ortega, G., Csordas, A., Hsu, A., Arroyo-Currás, N., et al. (2020). Real-time monitoring of a protein biomarker. ACS SENSORS, 5(7), 1877-1881 [10.1021/acssensors.0c01085].

Real-time monitoring of a protein biomarker

A. Idili;
2020-07-03

Abstract

The ability to monitor protein biomarkers continuously and in real-time would significantly advance the precision of medicine. Current protein-detection techniques, however, including ELISA and lateral flow assays, provide only time-delayed, single-time-point measurements, limiting their ability to guide prompt responses to rapidly evolving, life-threatening conditions. In response, here we present an electrochemical aptamer-based sensor (EAB) that supports high-frequency, real-time biomarker measurements. Specifically, we have developed an electrochemical, aptamer-based (EAB) sensor against Neutrophil Gelatinase-Associated Lipocalin (NGAL), a protein that, if present in urine at levels above a threshold value, is indicative of acute renal/kidney injury (AKI). When deployed inside a urinary catheter, the resulting reagentless, wash-free sensor supports real-time, high-frequency monitoring of clinically relevant NGAL concentrations over the course of hours. By providing an “early warning system”, the ability to measure levels of diagnostically relevant proteins such as NGAL in real-time could fundamentally change how we detect, monitor, and treat many important diseases.
3-lug-2020
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore CHIM/01 - CHIMICA ANALITICA
English
Con Impact Factor ISI
acute kidney injury; aptamer; electrochemical sensor; neutrophil gelatinase-associated lipocalin; real-time protein monitoring
Parolo, C., Idili, A., Ortega, G., Csordas, A., Hsu, A., Arroyo-Currás, N., et al. (2020). Real-time monitoring of a protein biomarker. ACS SENSORS, 5(7), 1877-1881 [10.1021/acssensors.0c01085].
Parolo, C; Idili, A; Ortega, G; Csordas, A; Hsu, A; Arroyo-Currás, N; Yang, Q; Ferguson, Bs; Wang, J; Plaxco, Kw
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
acssensors.0c01085_prot sens.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 2.13 MB
Formato Adobe PDF
2.13 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/312631
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 58
  • ???jsp.display-item.citation.isi??? 57
social impact