Objectives: To determine reference curves for fetal aortic and pulmonary valve annulus area by three-dimensional ultrasonography using the spatio-temporal image correlation (STIC) in the rendering mode, and to ascertain its applicability in congenital heart disease (CHD). Methods: We performed a retrospective cross-sectional study of 328 normal fetuses and 42 fetuses with CHD between 20 and 33 weeks 6 days of gestation. The outflow plane view of the great vessels was used to measure the areas of the valvar annuli, and the measurements were performed in systole. A linear regression model adjusted according to the determination coefficient (R2) was utilized to construct the reference intervals. The concordance correlation coefficient (CCC) was used to calculate the reproducibility of the mitral and tricuspid valve areas. Results: The mean ± standard deviation (SD) of the aortic and pulmonary valve annulus areas ranged from 6.6 ± 1.2 to 32.9 ± 1.1 mm2 and 10.7 ± 1.3 to 40.3 ± 1.2 mm2, respectively. We observed a linear relationship and strong positive correlation between the area of the aortic and pulmonary valve annuli with r=0.97 and 0.96, respectively. Good intra (CCC=0.99) and interobserver agreement (CCC=0.98) was observed for the measurement of the aortic valve annulus area. A good intra (CCC=0.99) and interobserver (CCC=0.97) agreement was also observed for the measurement of the pulmonary valve annulus area. The mean ± SD of the difference of the areas of the aortic and pulmonary valve annuli between the normal fetuses and those with CHD were -1.801 ± 1.429 mm2 (p=0.208) and -1.033 ± 1.467 mm2 (p<0.0001), respectively. Conclusions: The reference curves for the areas of the aortic and pulmonary valve annuli of fetal hearts were determined, and showed good inter and intraobserver reproducibility. The constructed reference curves showed applicability in different types of CHD.

Chagas, C.c., Siqueira Pontes, A.l., Bravo-Valenzuela, N.j., Peixoto, A.b., Mappa, I., Viscardi, C., et al. (2023). Assessment of fetal heart aortic and pulmonary valve annulus area by three-dimensional ultrasonography: reference curves and applicability in congenital heart diseases. JOURNAL OF PERINATAL MEDICINE, 0(0) [10.1515/jpm-2022-0532].

Assessment of fetal heart aortic and pulmonary valve annulus area by three-dimensional ultrasonography: reference curves and applicability in congenital heart diseases

Mappa, Ilenia;Rizzo, Giuseppe;
2023-01-02

Abstract

Objectives: To determine reference curves for fetal aortic and pulmonary valve annulus area by three-dimensional ultrasonography using the spatio-temporal image correlation (STIC) in the rendering mode, and to ascertain its applicability in congenital heart disease (CHD). Methods: We performed a retrospective cross-sectional study of 328 normal fetuses and 42 fetuses with CHD between 20 and 33 weeks 6 days of gestation. The outflow plane view of the great vessels was used to measure the areas of the valvar annuli, and the measurements were performed in systole. A linear regression model adjusted according to the determination coefficient (R2) was utilized to construct the reference intervals. The concordance correlation coefficient (CCC) was used to calculate the reproducibility of the mitral and tricuspid valve areas. Results: The mean ± standard deviation (SD) of the aortic and pulmonary valve annulus areas ranged from 6.6 ± 1.2 to 32.9 ± 1.1 mm2 and 10.7 ± 1.3 to 40.3 ± 1.2 mm2, respectively. We observed a linear relationship and strong positive correlation between the area of the aortic and pulmonary valve annuli with r=0.97 and 0.96, respectively. Good intra (CCC=0.99) and interobserver agreement (CCC=0.98) was observed for the measurement of the aortic valve annulus area. A good intra (CCC=0.99) and interobserver (CCC=0.97) agreement was also observed for the measurement of the pulmonary valve annulus area. The mean ± SD of the difference of the areas of the aortic and pulmonary valve annuli between the normal fetuses and those with CHD were -1.801 ± 1.429 mm2 (p=0.208) and -1.033 ± 1.467 mm2 (p<0.0001), respectively. Conclusions: The reference curves for the areas of the aortic and pulmonary valve annuli of fetal hearts were determined, and showed good inter and intraobserver reproducibility. The constructed reference curves showed applicability in different types of CHD.
2-gen-2023
Online ahead of print
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MED/40 - GINECOLOGIA E OSTETRICIA
English
fetus
heart
reference curves
three-dimensional ultrasonography
valves
Chagas, C.c., Siqueira Pontes, A.l., Bravo-Valenzuela, N.j., Peixoto, A.b., Mappa, I., Viscardi, C., et al. (2023). Assessment of fetal heart aortic and pulmonary valve annulus area by three-dimensional ultrasonography: reference curves and applicability in congenital heart diseases. JOURNAL OF PERINATAL MEDICINE, 0(0) [10.1515/jpm-2022-0532].
Chagas, Cc; Siqueira Pontes, Al; Bravo-Valenzuela, Nj; Peixoto, Ab; Mappa, I; Viscardi, C; Rizzo, G; Araujo Júnior, E
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/311099
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact