Objectives XR-hysterosalpingography currently represents the gold standard for tubal pathology evaluation. Magnetic resonance-HSG is an innovative technique. With our study, we aim to comprehend if and how MR-HSG, compared to traditional XR-HSG, could give us this additional information in the diagnostic/therapeutic process. Materials and methods This study included 19 patients between 30 and 42 years old (average age 37.7) affected by infertility. Patients underwent contextually both XR-HSG and MR-HSG, using a single catheterization. The dynamic MR-HSG exam consisted a MR sequence during contrast administration through the cervical catheter. Results Both XR-HSG and MR-HSG documented that 15 of the 19 patients had bilateral tubal patency, while four patients had monolateral tubal patency. However, MR-HSG allowed us to diagnose additional findings: Two active endometriosis foci in adnexal localization and a condition of adenomyosis A unicornuate uterus malformation A submucous uterine myoma near the tubal ostium A decrease of the ovarian reserve in a patient So MR-HSG could potentially detect in 10/19 (52%) women the cause of their infertility, compared to 4/19 (21%) detected with XR-HSG and about 30% of women would have resulted as false negatives if we only used XR-HSG. Finally, with a questionnaire, we demonstrated that MR-HSG is less painful than XR-HSG. Conclusions These data thus confirm that XR-HSG and MR-HSG present the same diagnostic of assessing tubal patency. We also demonstrated that MR-HSG is able to detect further collateral findings that could likewise be a possible therapeutic target and it could possibly become the new gold standard in female infertility diagnostics.

Pace, C., Argirò, R., Casadei, L., Cesareni, M., Orlacchio, A. (2022). Comparison between X-ray-hysterosalpingography and 3 Tesla magnetic resonance-hysterosalpingography in the assessment of the tubal patency in the cause of female infertility. LA RADIOLOGIA MEDICA, 1-10 [10.1007/s11547-022-01556-8].

Comparison between X-ray-hysterosalpingography and 3 Tesla magnetic resonance-hysterosalpingography in the assessment of the tubal patency in the cause of female infertility

Casadei, Luisa;Orlacchio, Antonio
2022-09-27

Abstract

Objectives XR-hysterosalpingography currently represents the gold standard for tubal pathology evaluation. Magnetic resonance-HSG is an innovative technique. With our study, we aim to comprehend if and how MR-HSG, compared to traditional XR-HSG, could give us this additional information in the diagnostic/therapeutic process. Materials and methods This study included 19 patients between 30 and 42 years old (average age 37.7) affected by infertility. Patients underwent contextually both XR-HSG and MR-HSG, using a single catheterization. The dynamic MR-HSG exam consisted a MR sequence during contrast administration through the cervical catheter. Results Both XR-HSG and MR-HSG documented that 15 of the 19 patients had bilateral tubal patency, while four patients had monolateral tubal patency. However, MR-HSG allowed us to diagnose additional findings: Two active endometriosis foci in adnexal localization and a condition of adenomyosis A unicornuate uterus malformation A submucous uterine myoma near the tubal ostium A decrease of the ovarian reserve in a patient So MR-HSG could potentially detect in 10/19 (52%) women the cause of their infertility, compared to 4/19 (21%) detected with XR-HSG and about 30% of women would have resulted as false negatives if we only used XR-HSG. Finally, with a questionnaire, we demonstrated that MR-HSG is less painful than XR-HSG. Conclusions These data thus confirm that XR-HSG and MR-HSG present the same diagnostic of assessing tubal patency. We also demonstrated that MR-HSG is able to detect further collateral findings that could likewise be a possible therapeutic target and it could possibly become the new gold standard in female infertility diagnostics.
27-set-2022
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MED/36 - DIAGNOSTICA PER IMMAGINI E RADIOTERAPIA
English
Dynamic contrast study
Female infertility
Hysterosalpingography with magnetic resonance
Pace, C., Argirò, R., Casadei, L., Cesareni, M., Orlacchio, A. (2022). Comparison between X-ray-hysterosalpingography and 3 Tesla magnetic resonance-hysterosalpingography in the assessment of the tubal patency in the cause of female infertility. LA RADIOLOGIA MEDICA, 1-10 [10.1007/s11547-022-01556-8].
Pace, C; Argirò, R; Casadei, L; Cesareni, M; Orlacchio, A
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
Comparison between X-ray-hysterosalpingography and 3 Tesla magnetic resonance-hysterosalpingography in the assessment of the tubal patency in the cause of female infertility.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Non specificato
Dimensione 2.09 MB
Formato Adobe PDF
2.09 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/309379
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 1
social impact