IL-6 detection is highly desirable since can monitor many diseases in humans and assess the response to treatments.Herein, two novel label-free voltammetric immunosensors for rapid and accurate interleukin-6 (IL-6) detection in human serum are presented. The immunosensors are fabricated by immobilising two different IL-6 antibodies, identified as mAb-IL-6 clone-5 and clone-7, on in-house produced screen-printed electrodes modified with inexpensive recycling biochar (Bio-SPEs). To ensure high structural fidelity and performance, an in-depth electrochemical characterization of the layer-by-layer assembly of the immunosensor was conducted by cyclic voltammetry (CV) and sensing was performed using square wave voltammetry (SWV). The two immunosensors showed good analytical performances in human serum, exhibiting a wide linear range (LR) between 26-125 and 30-138 pg/mL, a good limit of detection (LOD) of 4.8 and 5.4 pg/mL and selectivity for IL-6 over other common cytokines, including IL-1 beta and TNF-alpha. Performance comparison of IL-6 immunosensors with those of a commercial spectrophotometric ELISA kit (LOD of 20 pg/mL, RSD% of 15%) denotes a better sensitivity and reproducibility of the proposed label-free devices, associated with a reduced detection time (30 min instead of more than 3 h for ELISA test). Furthermore, the proposed immunosensors were successfully applied in blood samples (with only a dilution of 1:100 v/v in PBS and without additional treatments) with good sensitivity (LOD of 14.3 pg/mL) and reproducibility (RSD% < 11%), thus paving the way for their application as viable diagnostic and therapeutic point-of-care tools alternative to the IL-6 detection techniques routinely used (ELISA and Western Blot).

Cancelliere, R., Di Tinno, A., Maria Di Lellis, A., Contini, G., Micheli, L., Signori, E. (2022). Cost-effective and disposable label-free voltammetric immunosensor for sensitive detection of interleukin-6. BIOSENSORS & BIOELECTRONICS, 213 [10.1016/j.bios.2022.114467].

Cost-effective and disposable label-free voltammetric immunosensor for sensitive detection of interleukin-6

Giorgio Contini
;
Laura Micheli
;
2022-01-01

Abstract

IL-6 detection is highly desirable since can monitor many diseases in humans and assess the response to treatments.Herein, two novel label-free voltammetric immunosensors for rapid and accurate interleukin-6 (IL-6) detection in human serum are presented. The immunosensors are fabricated by immobilising two different IL-6 antibodies, identified as mAb-IL-6 clone-5 and clone-7, on in-house produced screen-printed electrodes modified with inexpensive recycling biochar (Bio-SPEs). To ensure high structural fidelity and performance, an in-depth electrochemical characterization of the layer-by-layer assembly of the immunosensor was conducted by cyclic voltammetry (CV) and sensing was performed using square wave voltammetry (SWV). The two immunosensors showed good analytical performances in human serum, exhibiting a wide linear range (LR) between 26-125 and 30-138 pg/mL, a good limit of detection (LOD) of 4.8 and 5.4 pg/mL and selectivity for IL-6 over other common cytokines, including IL-1 beta and TNF-alpha. Performance comparison of IL-6 immunosensors with those of a commercial spectrophotometric ELISA kit (LOD of 20 pg/mL, RSD% of 15%) denotes a better sensitivity and reproducibility of the proposed label-free devices, associated with a reduced detection time (30 min instead of more than 3 h for ELISA test). Furthermore, the proposed immunosensors were successfully applied in blood samples (with only a dilution of 1:100 v/v in PBS and without additional treatments) with good sensitivity (LOD of 14.3 pg/mL) and reproducibility (RSD% < 11%), thus paving the way for their application as viable diagnostic and therapeutic point-of-care tools alternative to the IL-6 detection techniques routinely used (ELISA and Western Blot).
2022
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore CHIM/01 - CHIMICA ANALITICA
English
Biochar; Electrochemical immunosensor; Green-nanocarbon; Interleukin-6; Label-free immunosensor; Point-of-care device; Cost-Benefit Analysis; Electrochemical Techniques; Electrodes; Humans; Immunoassay; Interleukin-6; Limit of Detection; Reproducibility of Results; Biosensing Techniques
Cancelliere, R., Di Tinno, A., Maria Di Lellis, A., Contini, G., Micheli, L., Signori, E. (2022). Cost-effective and disposable label-free voltammetric immunosensor for sensitive detection of interleukin-6. BIOSENSORS & BIOELECTRONICS, 213 [10.1016/j.bios.2022.114467].
Cancelliere, R; Di Tinno, A; Maria Di Lellis, A; Contini, G; Micheli, L; Signori, E
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
Proof_BIOS_114467.pdf

solo utenti autorizzati

Tipologia: Documento in Pre-print
Licenza: Copyright dell'editore
Dimensione 799.63 kB
Formato Adobe PDF
799.63 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/308276
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 19
social impact