Nowadays, radon gas exposure is considered one of the main health concerns for the population because, by carrying about half the total dose due to environmental radioactivity, it is the second cause of lung cancer after smoking. Due to a relatively long half-life of 3.82 days, the chemical inertia and since its parent Ra-226 is largely diffuse on the earth's crust and especially in the building materials, radon can diffuse and potentially saturate human habitats, with a concentration that can suddenly change during the 24 h day depending on temperature, pressure, and relative humidity. For such reasons, 'real-time' measurements performed by an active detector, possibly of small dimensions and a handy configuration, can play an important role in evaluating the risk and taking the appropriate countermeasures to mitigate it. In this work, a novel algorithm for pattern recognition was developed to exploit the potentialities of silicon active detectors with a pixel matrix structure to measure radon through the alpha emission, in a simple measurement configuration, where the device is placed directly in air with no holder, no collection filter or electrostatic field to drift the radon progenies towards the detector active area. This particular measurement configuration (dubbed as bare) requires an alpha/beta-discrimination method that is not based on spectroscopic analysis: as the gas surrounds the detector the alpha particles are emitted at different distances from it, so they lose variable energy amount in air depending on the traveled path-length which implies a variable deposited energy in the active area. The pixels matrix structure allows overcoming this issue because the interaction of alpha, beta and gamma particles generate in the active area of the detector clusters (group of pixels where a signal is read) of different shape and energy dispersion. The novel algorithm that exploits such a phenomenon was developed using a pixelated silicon detector of the TimePix family with a compact design. An alpha (Am-241) and a beta (Sr-90) source were used to calibrate the algorithm and to evaluate its performances in terms of beta rejection capability and alpha recognition efficiency. Successively, the detector was exposed to different radon concentrations at the ENEA-INMRI radon facility in 'bare' configuration, in order to check the linearity of the device response over a radon concentration range. The results for this technique are presented and discussed, highlighting the potential applications especially the possibility to exploit small and handy detectors to perform radon active measurements in the simplest configuration.

Rizzo, A., Cardellini, F., Poggi, C., Borra, E., Ciciani, L., Narici, L., et al. (2022). Novel algorithm for radon real-time measurements with a pixelated detector. SENSORS, 22(2) [10.3390/s22020516].

Novel algorithm for radon real-time measurements with a pixelated detector

Narici, Livio;
2022-01-10

Abstract

Nowadays, radon gas exposure is considered one of the main health concerns for the population because, by carrying about half the total dose due to environmental radioactivity, it is the second cause of lung cancer after smoking. Due to a relatively long half-life of 3.82 days, the chemical inertia and since its parent Ra-226 is largely diffuse on the earth's crust and especially in the building materials, radon can diffuse and potentially saturate human habitats, with a concentration that can suddenly change during the 24 h day depending on temperature, pressure, and relative humidity. For such reasons, 'real-time' measurements performed by an active detector, possibly of small dimensions and a handy configuration, can play an important role in evaluating the risk and taking the appropriate countermeasures to mitigate it. In this work, a novel algorithm for pattern recognition was developed to exploit the potentialities of silicon active detectors with a pixel matrix structure to measure radon through the alpha emission, in a simple measurement configuration, where the device is placed directly in air with no holder, no collection filter or electrostatic field to drift the radon progenies towards the detector active area. This particular measurement configuration (dubbed as bare) requires an alpha/beta-discrimination method that is not based on spectroscopic analysis: as the gas surrounds the detector the alpha particles are emitted at different distances from it, so they lose variable energy amount in air depending on the traveled path-length which implies a variable deposited energy in the active area. The pixels matrix structure allows overcoming this issue because the interaction of alpha, beta and gamma particles generate in the active area of the detector clusters (group of pixels where a signal is read) of different shape and energy dispersion. The novel algorithm that exploits such a phenomenon was developed using a pixelated silicon detector of the TimePix family with a compact design. An alpha (Am-241) and a beta (Sr-90) source were used to calibrate the algorithm and to evaluate its performances in terms of beta rejection capability and alpha recognition efficiency. Successively, the detector was exposed to different radon concentrations at the ENEA-INMRI radon facility in 'bare' configuration, in order to check the linearity of the device response over a radon concentration range. The results for this technique are presented and discussed, highlighting the potential applications especially the possibility to exploit small and handy detectors to perform radon active measurements in the simplest configuration.
10-gen-2022
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore FIS/07 - FISICA APPLICATA (A BENI CULTURALI, AMBIENTALI, BIOLOGIA E MEDICINA)
English
Con Impact Factor ISI
MediPix; TimePix; pattern recognition algorithm; radon; real-time measurements; Algorithms; Humans; Radon Daughters; Air Pollutants, Radioactive; Radiation Monitoring; Radon
Rizzo, A., Cardellini, F., Poggi, C., Borra, E., Ciciani, L., Narici, L., et al. (2022). Novel algorithm for radon real-time measurements with a pixelated detector. SENSORS, 22(2) [10.3390/s22020516].
Rizzo, A; Cardellini, F; Poggi, C; Borra, E; Ciciani, L; Narici, L; Sperandio, L; Vilardi, I
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/306696
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact