PURPOSE: To observe the refractive outcomes of cataract surgery in small adult eyes, and to investigate the accuracy of different intraocular lens (IOL) power prediction formulas.DESIGN: Retrospective interventional case series.METHODS: We included consecutive small eyes undergoing uneventful phacoemulsification cataract surgery with a single highly powerful IOL (Acrysof SA60AT) implanted in the capsular bag (range of powers +35.0 to +40.0 diopters [D]), at the Cataract Centre for Moorfields Eye Hospital. Exclusion criteria were combined or previous intraocular surgical procedures, and any type of intraoperative complications. Main outcome measures were mean prediction errors with Hoffer Q, Holladay 1, Holladay 2, Haigis, SRK-T, and SRK-II IOL power prediction formulas and proportions of eyes achieving absolute errors within the dioptric ranges of 0.5, 1.0, and 2.0 D of target and emmetropia, respectively. The ANOVA test was used to compare the refractive results among various formulas.RESULTS: Twenty-eight eyes were studied; the mean numerical error was 0.22 +/- 1.22 D and the mean absolute error was 0.95 +/- 0.78 D with the adopted Hoffer Q formula; 39%, 61%, and 89% of the eyes had a final refraction within 0.5 D, 1.0 D, and 2.0 D of target, respectively. None of the latest-generation formulas significantly outperformed the others (P = .245).CONCLUSIONS: The Hoffer Q formula led to good or fair refractive outcomes in less than two thirds of the cases. With Holladay 1 and 2 and Haigis formulas, outcomes would have not been significantly different. The SRK formulas yielded less accurate predictions. Possible reasons are discussed. (C) 2015 Elsevier Inc. All rights reserved
Carifi, G., Aiello, F., Zygoura, V., Kopsachilis, N., Maurino, V. (2015). Accuracy of the refractive prediction determined by multiple currently available intraocular lens power calculation formulas in small eyes. AMERICAN JOURNAL OF OPHTHALMOLOGY, 159(3), 577-583 [10.1016/j.ajo.2014.11.036].
Accuracy of the refractive prediction determined by multiple currently available intraocular lens power calculation formulas in small eyes
Aiello F.;
2015-01-01
Abstract
PURPOSE: To observe the refractive outcomes of cataract surgery in small adult eyes, and to investigate the accuracy of different intraocular lens (IOL) power prediction formulas.DESIGN: Retrospective interventional case series.METHODS: We included consecutive small eyes undergoing uneventful phacoemulsification cataract surgery with a single highly powerful IOL (Acrysof SA60AT) implanted in the capsular bag (range of powers +35.0 to +40.0 diopters [D]), at the Cataract Centre for Moorfields Eye Hospital. Exclusion criteria were combined or previous intraocular surgical procedures, and any type of intraoperative complications. Main outcome measures were mean prediction errors with Hoffer Q, Holladay 1, Holladay 2, Haigis, SRK-T, and SRK-II IOL power prediction formulas and proportions of eyes achieving absolute errors within the dioptric ranges of 0.5, 1.0, and 2.0 D of target and emmetropia, respectively. The ANOVA test was used to compare the refractive results among various formulas.RESULTS: Twenty-eight eyes were studied; the mean numerical error was 0.22 +/- 1.22 D and the mean absolute error was 0.95 +/- 0.78 D with the adopted Hoffer Q formula; 39%, 61%, and 89% of the eyes had a final refraction within 0.5 D, 1.0 D, and 2.0 D of target, respectively. None of the latest-generation formulas significantly outperformed the others (P = .245).CONCLUSIONS: The Hoffer Q formula led to good or fair refractive outcomes in less than two thirds of the cases. With Holladay 1 and 2 and Haigis formulas, outcomes would have not been significantly different. The SRK formulas yielded less accurate predictions. Possible reasons are discussed. (C) 2015 Elsevier Inc. All rights reservedI documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.