Different corrole derivatives have been exploited as ionophores for the development of ion-selective electrodes (ISEs). The compounds used are free-base 5,10,15-triphenylcorrole, the corresponding Mn and Fe chloride complexes, the Cu complex of 5,10,15-tris(4-tert-butylphenyl)- corrole and the Fe chloride complex of 2,3,17,18-tetraethyl,7,8,12,13-tetramethylcorrole. Corroles have been dispersed in the polyvinyl chloride polymeric matrix and different plasticizers have been used for the preparation of selective membranes. The developed ISEs have been tested for the detection of model analytes and the working mechanism has been investigated in detail. In the case of free-base corrole, the results showed that it is diffi cult to obtain high selective ISEs, due to the macrocycle high sensitivity to the background solution pH. On the other hand, Mn derivative are shown to be highly selective for chloride ion detection, with performances superior to the corresponding Mn porphyrin-based ISEs. Finally both Cu and Fe derivatives are very promising ionophores for the detection of hydrophilic anions, such as carbonate and monohydrogen phosphate ion.

Lvova, L., Di Natale, C., D'Amico, A., Paolesse, R. (2009). Corrole-based ion-selective electrodes. JOURNAL OF PORPHYRINS AND PHTHALOCYANINES, 13(11), 1168-1178 [10.1142/S1088424609001510].

Corrole-based ion-selective electrodes

Lvova L.;Di Natale C.;D'Amico A.;Paolesse R.
2009-01-01

Abstract

Different corrole derivatives have been exploited as ionophores for the development of ion-selective electrodes (ISEs). The compounds used are free-base 5,10,15-triphenylcorrole, the corresponding Mn and Fe chloride complexes, the Cu complex of 5,10,15-tris(4-tert-butylphenyl)- corrole and the Fe chloride complex of 2,3,17,18-tetraethyl,7,8,12,13-tetramethylcorrole. Corroles have been dispersed in the polyvinyl chloride polymeric matrix and different plasticizers have been used for the preparation of selective membranes. The developed ISEs have been tested for the detection of model analytes and the working mechanism has been investigated in detail. In the case of free-base corrole, the results showed that it is diffi cult to obtain high selective ISEs, due to the macrocycle high sensitivity to the background solution pH. On the other hand, Mn derivative are shown to be highly selective for chloride ion detection, with performances superior to the corresponding Mn porphyrin-based ISEs. Finally both Cu and Fe derivatives are very promising ionophores for the detection of hydrophilic anions, such as carbonate and monohydrogen phosphate ion.
2009
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore CHIM/07 - FONDAMENTI CHIMICI DELLE TECNOLOGIE
Settore ING-INF/01 - ELETTRONICA
English
corrole, ionophore, ion-selective polymeric membrane, potentiometric sensors
Lvova, L., Di Natale, C., D'Amico, A., Paolesse, R. (2009). Corrole-based ion-selective electrodes. JOURNAL OF PORPHYRINS AND PHTHALOCYANINES, 13(11), 1168-1178 [10.1142/S1088424609001510].
Lvova, L; Di Natale, C; D'Amico, A; Paolesse, R
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
Corrole-based ion-selective electrodes_JPP_2009.pdf

solo utenti autorizzati

Descrizione: Articolo principale
Tipologia: Documento in Post-print
Licenza: Copyright dell'editore
Dimensione 637.7 kB
Formato Adobe PDF
637.7 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/253473
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 24
social impact