Background: Poor self-care in patients with hypertension is associated with worse patient outcomes. The Self- Care of Hypertension Inventory (SC-HI) measures self-care in patients with hypertension and includes three scales: self-care maintenance, which measures adherence to prescribed treatments and behaviors; self-care management, which evaluates the responses to signs and symptoms of high blood pressure; and self-care confidence, which measures self-efficacy in dealing with the entire process. Objective: To test the psychometric characteristics of the Brazilian version of the SC-HI. Methods: We enrolled a sample of 360 patients with hypertension and performed confirmatory factor analysis (CFA) and exploratory factor analysis (EFA) to test the factorial structure of the SC-HI and computed the factor score determinacy coefficient to evaluate the SC-HI internal consistency reliability. Results: The sample was predominantly female (65%), mean age of 65 years (SD = 10), white (70%). The selfcare maintenance scale resulted in a unidimensional scale, with supportive fit indices (CFI = 0.901, RMSEA = 0.048); the self-care management did not reflect the original factorial structure and had unsupportive fit indices. EFA showed a different factorial solution in reference to the original study. Finally, the selfcare confidence scale resulted in a unidimensional scale with supportive fit indices (CFI = 0.940, RMSEA = 0.093). The reliability of the self-care maintenance, management, and confidence scales resulted in factor score determinacy coefficients of 0.83, 0.78, and 0.97 respectively. Conclusion: This study shows that the SC-HI is a valid and reliable tool to measure self-care in patients with hypertension among the Brazilian population.

Silveira, L., De Maria, M., Dickson, V.v., Avila, C.w., Rabelo-Silva, E.r., Vellone, E. (2020). Validity and reliability of the self-care of hypertension inventory (SC-HI) in a Brazilian population. HEART & LUNG, 49(5), 518-523 [10.1016/j.hrtlng.2020.02.048].

Validity and reliability of the self-care of hypertension inventory (SC-HI) in a Brazilian population

De Maria, Maddalena;Vellone, Ercole
2020-03-16

Abstract

Background: Poor self-care in patients with hypertension is associated with worse patient outcomes. The Self- Care of Hypertension Inventory (SC-HI) measures self-care in patients with hypertension and includes three scales: self-care maintenance, which measures adherence to prescribed treatments and behaviors; self-care management, which evaluates the responses to signs and symptoms of high blood pressure; and self-care confidence, which measures self-efficacy in dealing with the entire process. Objective: To test the psychometric characteristics of the Brazilian version of the SC-HI. Methods: We enrolled a sample of 360 patients with hypertension and performed confirmatory factor analysis (CFA) and exploratory factor analysis (EFA) to test the factorial structure of the SC-HI and computed the factor score determinacy coefficient to evaluate the SC-HI internal consistency reliability. Results: The sample was predominantly female (65%), mean age of 65 years (SD = 10), white (70%). The selfcare maintenance scale resulted in a unidimensional scale, with supportive fit indices (CFI = 0.901, RMSEA = 0.048); the self-care management did not reflect the original factorial structure and had unsupportive fit indices. EFA showed a different factorial solution in reference to the original study. Finally, the selfcare confidence scale resulted in a unidimensional scale with supportive fit indices (CFI = 0.940, RMSEA = 0.093). The reliability of the self-care maintenance, management, and confidence scales resulted in factor score determinacy coefficients of 0.83, 0.78, and 0.97 respectively. Conclusion: This study shows that the SC-HI is a valid and reliable tool to measure self-care in patients with hypertension among the Brazilian population.
16-mar-2020
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MED/45 - SCIENZE INFERMIERISTICHE GENERALI, CLINICHE E PEDIATRICHE
English
Behavior rating scale
Hypertension
Self-care
Silveira, L., De Maria, M., Dickson, V.v., Avila, C.w., Rabelo-Silva, E.r., Vellone, E. (2020). Validity and reliability of the self-care of hypertension inventory (SC-HI) in a Brazilian population. HEART & LUNG, 49(5), 518-523 [10.1016/j.hrtlng.2020.02.048].
Silveira, Lcj; De Maria, M; Dickson, Vv; Avila, Cw; Rabelo-Silva, Er; Vellone, E
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
Silveira_2020_ psychometrics SC-HI in brazil.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 359.65 kB
Formato Adobe PDF
359.65 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/253306
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 11
social impact