The Coleman technique is universally recognized as the gold standard for fat transfer, but although effective, it is tedious, time consuming, and costly. This report proposes a new and more efficient method of fat grafting (simplified lipostructure).This report introduces a modification of the standard Coleman transfer and injection technique, performed by connecting a 10-ml syringe to a 1-ml syringe and to a blunt infiltrating cannula through a "three-way stopcock valve." The study retrospectively evaluated two groups of patients who had undergone either Coleman or simplified lipostructure, comparing surgical staff, operative time, volume of infiltrated fat, cosmetic outcome, and complications. Statistical analyses were conducted using the Wilcoxon rank sum test and Spearman's rank-order correlation.The simplified lipostructure group compared with Coleman lipostructure showed a reduced operative staff (1 vs. 2 members), a reduced operative time (66 vs. 74.2 min) (alpha = 0.0035), and an increased volume of infiltrated fat (167.2 vs. 138.7 ml) (p < 0.0001) while retaining comparable cosmetic results (7.45 vs. 7.25; visual analog scale 0-10), and only minor complications.The three-way stopcock valve system appears to be a smart technical solution that eases syringe refilling, improves fat transplantation times, and reduces costs. The findings show this technical modification to be easy and effective. The authors therefore recommend it to all surgeons performing fat transfer.This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.

Paolini, G., Amoroso, M., Longo, B., Sorotos, M., Karypidis, D., Santanelli Di Pompeo, F. (2014). Simplified lipostructure: A technical note. AESTHETIC PLASTIC SURGERY, 38(1), 78-82 [10.1007/s00266-013-0254-6].

Simplified lipostructure: A technical note

Longo B.;
2014-01-01

Abstract

The Coleman technique is universally recognized as the gold standard for fat transfer, but although effective, it is tedious, time consuming, and costly. This report proposes a new and more efficient method of fat grafting (simplified lipostructure).This report introduces a modification of the standard Coleman transfer and injection technique, performed by connecting a 10-ml syringe to a 1-ml syringe and to a blunt infiltrating cannula through a "three-way stopcock valve." The study retrospectively evaluated two groups of patients who had undergone either Coleman or simplified lipostructure, comparing surgical staff, operative time, volume of infiltrated fat, cosmetic outcome, and complications. Statistical analyses were conducted using the Wilcoxon rank sum test and Spearman's rank-order correlation.The simplified lipostructure group compared with Coleman lipostructure showed a reduced operative staff (1 vs. 2 members), a reduced operative time (66 vs. 74.2 min) (alpha = 0.0035), and an increased volume of infiltrated fat (167.2 vs. 138.7 ml) (p < 0.0001) while retaining comparable cosmetic results (7.45 vs. 7.25; visual analog scale 0-10), and only minor complications.The three-way stopcock valve system appears to be a smart technical solution that eases syringe refilling, improves fat transplantation times, and reduces costs. The findings show this technical modification to be easy and effective. The authors therefore recommend it to all surgeons performing fat transfer.This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.
2014
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MED/19 - CHIRURGIA PLASTICA
English
Con Impact Factor ISI
Lipostructure; Lipofilling; Lipografting; Fat transplant; Adipose tissue; Coleman technique; Adipose Tissue; Adult; Aged; Equipment Design; Humans; Middle Aged; Reconstructive Surgical Procedures; Retrospective Studies; Cosmetic Techniques
Paolini, G., Amoroso, M., Longo, B., Sorotos, M., Karypidis, D., Santanelli Di Pompeo, F. (2014). Simplified lipostructure: A technical note. AESTHETIC PLASTIC SURGERY, 38(1), 78-82 [10.1007/s00266-013-0254-6].
Paolini, G; Amoroso, M; Longo, B; Sorotos, M; Karypidis, D; Santanelli Di Pompeo, F
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/247270
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 11
social impact