BACKGROUND: The woven endobridge intrasaccular flow disruptor (WEB) device for ruptured broad-based intracranial aneurysm (rBBA) remains underrepresented in existing studies. In this case series, the safety and efficacy results of the use of WEB in rBBA were evaluated from a multi-center experience.MATERIALS AND METHODS: Between November 2014 and October 2017, data of all patients with rBBA (>= 4 mm and/or dome/neck ratio >= 1 and >= 1.6) treated with WEB were prospectively collected and retrospectively analyzed from 3 Italian neurointerventional centers. The interventional procedures and the clinical and angiographic outcomes are reported for the periprocedural phase with midterm follow-up.RESULTS: 33 patients were included in this series (10 patients with Hunt-Hess scores 4-5; 23 patients with Hunt-Hess scores 1-3). Technical success was obtained for all 33 patients (100%). The mean fluoroscopy time was 24 minutes (range, 8-40 minutes). Adjunctive devices were used in 6% of patients (2 stents). At the 1-month follow-up visit, the overall mortality was 33%. The overall rate of WEB-related complications was 27% (5 device protrusion, 2 sac perforation, 2 thromboembolism), with a WEB-related mortality of 12% and permanent neurologic deficit of 3%. Of the surviving patients, 1 was lost to follow-up. At 14 months, the mean follow-up (range, 2-35 months), no early or delayed reruptured aneurysms were observed; complete occlusion was obtained in 7/21 patients (33%), neck remnant in 8/21 (38%), and residual aneurysm filling in 6/21 (29%) patients, with a modified Rankin Scale of 0sto 2 observed in 17/21 patients (80%).CONCLUSIONS: The WEB device for rBBA is a fast and effective treatment, with a low rate of aneurysm rebleeding; however, procedure-related complications seem not negligible. Further evaluation comparing this device with other treatment options should be performed.

Da Ros, V., Bozzi, A., Comelli, C., Semeraro, V., Comelli, S., Lucarelli, N., et al. (2019). Ruptured Intracranial Aneurysms Treated with Woven Endobridge Intrasaccular Flow Disruptor: A Multicenter Experience. WORLD NEUROSURGERY, 122, e498-e505 [10.1016/j.wneu.2018.10.088].

Ruptured Intracranial Aneurysms Treated with Woven Endobridge Intrasaccular Flow Disruptor: A Multicenter Experience

Da Ros V.;Gandini R.
2019-02-01

Abstract

BACKGROUND: The woven endobridge intrasaccular flow disruptor (WEB) device for ruptured broad-based intracranial aneurysm (rBBA) remains underrepresented in existing studies. In this case series, the safety and efficacy results of the use of WEB in rBBA were evaluated from a multi-center experience.MATERIALS AND METHODS: Between November 2014 and October 2017, data of all patients with rBBA (>= 4 mm and/or dome/neck ratio >= 1 and >= 1.6) treated with WEB were prospectively collected and retrospectively analyzed from 3 Italian neurointerventional centers. The interventional procedures and the clinical and angiographic outcomes are reported for the periprocedural phase with midterm follow-up.RESULTS: 33 patients were included in this series (10 patients with Hunt-Hess scores 4-5; 23 patients with Hunt-Hess scores 1-3). Technical success was obtained for all 33 patients (100%). The mean fluoroscopy time was 24 minutes (range, 8-40 minutes). Adjunctive devices were used in 6% of patients (2 stents). At the 1-month follow-up visit, the overall mortality was 33%. The overall rate of WEB-related complications was 27% (5 device protrusion, 2 sac perforation, 2 thromboembolism), with a WEB-related mortality of 12% and permanent neurologic deficit of 3%. Of the surviving patients, 1 was lost to follow-up. At 14 months, the mean follow-up (range, 2-35 months), no early or delayed reruptured aneurysms were observed; complete occlusion was obtained in 7/21 patients (33%), neck remnant in 8/21 (38%), and residual aneurysm filling in 6/21 (29%) patients, with a modified Rankin Scale of 0sto 2 observed in 17/21 patients (80%).CONCLUSIONS: The WEB device for rBBA is a fast and effective treatment, with a low rate of aneurysm rebleeding; however, procedure-related complications seem not negligible. Further evaluation comparing this device with other treatment options should be performed.
feb-2019
Pubblicato
Rilevanza internazionale
Articolo
Sì, ma tipo non specificato
Settore MED/36 - DIAGNOSTICA PER IMMAGINI E RADIOTERAPIA
English
Angioplasty; Aortic arch reconstruction; Stroke; Adult; Aged; Aged, 80 and over; Aneurysm, Ruptured; Female; Humans; Intracranial Aneurysm; Male; Middle Aged; Treatment Outcome; Blood Vessel Prosthesis
Da Ros, V., Bozzi, A., Comelli, C., Semeraro, V., Comelli, S., Lucarelli, N., et al. (2019). Ruptured Intracranial Aneurysms Treated with Woven Endobridge Intrasaccular Flow Disruptor: A Multicenter Experience. WORLD NEUROSURGERY, 122, e498-e505 [10.1016/j.wneu.2018.10.088].
Da Ros, V; Bozzi, A; Comelli, C; Semeraro, V; Comelli, S; Lucarelli, N; Burdi, N; Gandini, R
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/234033
Citazioni
  • ???jsp.display-item.citation.pmc??? 14
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 25
social impact