Periodic echocardiographic evaluation of valve function is recommended in all patients with prosthetic valves. Usually trans-thoracic echocardiography (TTE) is satisfactory to assess prosthetic function. Nevertheless when the TTE is suboptimal or in case of strong clinical doubt of prosthetic valve dysfunction, trans-esophageal echocardiography (TEE) remains the gold standard of imaging. Recent advancements in echocardiography, with the three-dimensional (3D) reconstruction, provide an incremental diagnostic value as compared to two-dimensional TEE. In addition, 3D-TEE gives unique views that add extra morphological and anatomical information, providing a very accurate presurgical evaluation.

Scandura, S., Cammalleri, V., Caggegi, A., Castello, A., Ronsivalle, G., Dipasqua, F., et al. (2013). Three-dimensional echocardiographic and surgical findings in mitral mechanical valve dysfunction. JOURNAL OF CARDIOVASCULAR MEDICINE, 14(4), 317-318 [10.2459/JCM.0b013e328356a3e0].

Three-dimensional echocardiographic and surgical findings in mitral mechanical valve dysfunction

Cammalleri V.;
2013-01-01

Abstract

Periodic echocardiographic evaluation of valve function is recommended in all patients with prosthetic valves. Usually trans-thoracic echocardiography (TTE) is satisfactory to assess prosthetic function. Nevertheless when the TTE is suboptimal or in case of strong clinical doubt of prosthetic valve dysfunction, trans-esophageal echocardiography (TEE) remains the gold standard of imaging. Recent advancements in echocardiography, with the three-dimensional (3D) reconstruction, provide an incremental diagnostic value as compared to two-dimensional TEE. In addition, 3D-TEE gives unique views that add extra morphological and anatomical information, providing a very accurate presurgical evaluation.
2013
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MED/11 - MALATTIE DELL'APPARATO CARDIOVASCOLARE
English
prosthesis thrombosis; prosthetic dysfunction; three-dimensional trans-esophageal echocardiography; Aged; Echocardiography, Three-Dimensional; Echocardiography, Transesophageal; Female; Heart Valve Diseases; Humans; Mitral Valve; Thrombosis; Heart Valve Prosthesis; Prosthesis Failure
Scandura, S., Cammalleri, V., Caggegi, A., Castello, A., Ronsivalle, G., Dipasqua, F., et al. (2013). Three-dimensional echocardiographic and surgical findings in mitral mechanical valve dysfunction. JOURNAL OF CARDIOVASCULAR MEDICINE, 14(4), 317-318 [10.2459/JCM.0b013e328356a3e0].
Scandura, S; Cammalleri, V; Caggegi, A; Castello, A; Ronsivalle, G; Dipasqua, F; Arcidiacono, Aa; Indelicato, A; Mignosa, C; Tamburino, C
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/228589
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact