Microdosemeters are frequently used today to specify the radiation quality in the framework of ion-beam therapy. The heterogeneity of the detector shapes and the materials limits the possibility of comparing directly spectra and mean lineal energies. A method was recently studied to convert the spectra obtained with unidirectional ion beams in slab detectors to those obtained with detectors of different in shape and material. The method is based on the observation that the lineal-energy spectra of slab detector, in a restricted energy interval, approximate the Linear Energy Transfer distributions at corresponding material and particle type and energies. In this study, the experimental spectra collected with a slab diamond detector are converted to the spectra that would be obtained using water detectors of spherical and cylindrical shapes.

Magrin, G., Verona, C., Verona-Rinati, G., Stock, M. (2019). MICRODOSIMETRY OF CLINICAL ION BEAMS: CONVERTING SPECTRA FROM DIAMOND SLAB TO WATER OF DIFFERENT SHAPES. RADIATION PROTECTION DOSIMETRY, 183(1-2), 167-171 [10.1093/rpd/ncy228].

MICRODOSIMETRY OF CLINICAL ION BEAMS: CONVERTING SPECTRA FROM DIAMOND SLAB TO WATER OF DIFFERENT SHAPES

Verona C.;Verona-Rinati G.;
2019-01-01

Abstract

Microdosemeters are frequently used today to specify the radiation quality in the framework of ion-beam therapy. The heterogeneity of the detector shapes and the materials limits the possibility of comparing directly spectra and mean lineal energies. A method was recently studied to convert the spectra obtained with unidirectional ion beams in slab detectors to those obtained with detectors of different in shape and material. The method is based on the observation that the lineal-energy spectra of slab detector, in a restricted energy interval, approximate the Linear Energy Transfer distributions at corresponding material and particle type and energies. In this study, the experimental spectra collected with a slab diamond detector are converted to the spectra that would be obtained using water detectors of spherical and cylindrical shapes.
2019
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore FIS/01 - FISICA SPERIMENTALE
English
Magrin, G., Verona, C., Verona-Rinati, G., Stock, M. (2019). MICRODOSIMETRY OF CLINICAL ION BEAMS: CONVERTING SPECTRA FROM DIAMOND SLAB TO WATER OF DIFFERENT SHAPES. RADIATION PROTECTION DOSIMETRY, 183(1-2), 167-171 [10.1093/rpd/ncy228].
Magrin, G; Verona, C; Verona-Rinati, G; Stock, M
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/218747
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 1
social impact