Patient-prosthesis mismatch (PPM) is a controversial issue in current clinical practice. PPM has been reported to have a negative impact on patients' prognosis after aortic valve replacement in several studies, showing increased all-cause and cardiac mortality. Moreover, a close relationship has recently been described between PPM and structural valve deterioration in biological prostheses. In patients at risk for PPM, several issues should be considered, and in the current era of cardiac surgery, preoperative planning should consider the different types of valves available and the various surgical techniques that can be used to prevent PPM. The present paper analyses the state of the art of the PPM issue.

Nardi, P., Russo, M., Saitto, G., Ruvolo, G. (2018). The prognostic significance of patient-prosthesis mismatch after aortic valve replacement. THE KOREAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 51(3), 161-166 [10.5090/kjtcs.2018.51.3.161].

The prognostic significance of patient-prosthesis mismatch after aortic valve replacement

Nardi P.;Ruvolo G.
2018-01-01

Abstract

Patient-prosthesis mismatch (PPM) is a controversial issue in current clinical practice. PPM has been reported to have a negative impact on patients' prognosis after aortic valve replacement in several studies, showing increased all-cause and cardiac mortality. Moreover, a close relationship has recently been described between PPM and structural valve deterioration in biological prostheses. In patients at risk for PPM, several issues should be considered, and in the current era of cardiac surgery, preoperative planning should consider the different types of valves available and the various surgical techniques that can be used to prevent PPM. The present paper analyses the state of the art of the PPM issue.
2018
Pubblicato
Rilevanza internazionale
Articolo
Comitato scientifico
Settore MED/23 - CHIRURGIA CARDIACA
English
Aortic valve replacement; Patient-prosthesis mismatch; Prognostic significance
Nardi, P., Russo, M., Saitto, G., Ruvolo, G. (2018). The prognostic significance of patient-prosthesis mismatch after aortic valve replacement. THE KOREAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 51(3), 161-166 [10.5090/kjtcs.2018.51.3.161].
Nardi, P; Russo, M; Saitto, G; Ruvolo, G
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/217685
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 7
  • ???jsp.display-item.citation.isi??? ND
social impact