The irreversible conductivity decay exhibited by Nafion 117 membranes above certain values of temperature and relative humidity (RH) has been investigated by two-probe impedance measurements carried out at 120 degrees C with the electric field normal to the membrane surface, under controlled applied pressure on the electrodes. The analysis of the evolution of both frequency response and normal conductivity during the decay has suggested that the decay arises from changes in the bulk transport properties of the Nafion membrane. This has been confirmed by determining, under stability conditions, the conductivity of membranes pre-treated under decay conditions. The results of these measurements have shown that the decay occurs only if the membrane undergoes an anisotropic deformation along the direction parallel to the electrode surface. Four-probe impedance measurements with the electric field parallel to the membrane surface have also been carried out to determine the membrane tangential conductivity before and after the decay. Comparison of normal and tangential conductivity has indicated that the decay is associated, to a certain extent, with an increase in the conduction anisotropy. (c) 2006 Elsevier B.V. All rights reserved.

Casciola, M., Alberti, G., Sganappa, M., Narducci, R. (2006). On the decay of Nafion proton conductivity at high temperature and relative humidity. JOURNAL OF POWER SOURCES, 162(1), 141-145 [10.1016/j.jpowsour.2006.06.023].

On the decay of Nafion proton conductivity at high temperature and relative humidity

Narducci R.
2006-11-01

Abstract

The irreversible conductivity decay exhibited by Nafion 117 membranes above certain values of temperature and relative humidity (RH) has been investigated by two-probe impedance measurements carried out at 120 degrees C with the electric field normal to the membrane surface, under controlled applied pressure on the electrodes. The analysis of the evolution of both frequency response and normal conductivity during the decay has suggested that the decay arises from changes in the bulk transport properties of the Nafion membrane. This has been confirmed by determining, under stability conditions, the conductivity of membranes pre-treated under decay conditions. The results of these measurements have shown that the decay occurs only if the membrane undergoes an anisotropic deformation along the direction parallel to the electrode surface. Four-probe impedance measurements with the electric field parallel to the membrane surface have also been carried out to determine the membrane tangential conductivity before and after the decay. Comparison of normal and tangential conductivity has indicated that the decay is associated, to a certain extent, with an increase in the conduction anisotropy. (c) 2006 Elsevier B.V. All rights reserved.
nov-2006
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore CHIM/03 - CHIMICA GENERALE E INORGANICA
Settore CHIM/07 - FONDAMENTI CHIMICI DELLE TECNOLOGIE
English
Nafion membrane; proton conductivity; high temperature; high relative humidity; anisotropic swelling
Casciola, M., Alberti, G., Sganappa, M., Narducci, R. (2006). On the decay of Nafion proton conductivity at high temperature and relative humidity. JOURNAL OF POWER SOURCES, 162(1), 141-145 [10.1016/j.jpowsour.2006.06.023].
Casciola, M; Alberti, G; Sganappa, M; Narducci, R
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/217324
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 205
  • ???jsp.display-item.citation.isi??? 194
social impact