Real-time and comfortable monitoring of the human breathing could allow identifying anomalies in the rhythm and waveform to be correlated with several pathologic disorders of respiratory and cardiovascular systems. A wireless sensor based on a flexible Kapton substrate, suitable to be stuck over the face skin like a plaster and provided with a graphene-oxide (GO) electrode, is here proposed for application to the monitoring of the moisture emitted during inhalations and exhalations. The GO-based electrode increases its dc resistance when exposed to humidity with a sensitivity of 60Ω/RH. The device is compatible with the radiofrequency identification (RFID) standard in the UHF band. When used in battery-less mode, it can be read up to 60 cm. The RFID sensor has been successfully experimented in a measurement campaign involving 10 volunteers asked to reproduce a set of predefined normal and pathological breaths. The resulting resistance traces permit to well clusterize the breath patterns with respect to the respiration rate (extracted by a fast Fourier transform) and to the average peak variation of the sensor's resistance with an accuracy close to 90%.
Caccami, M.c., Mulla, M., Occhiuzzi, C., Di Natale, C., Marrocco, G. (2018). Design and Experimentation of a Batteryless On-Skin RFID Graphene-Oxide Sensor for the Monitoring and Discrimination of Breath Anomalies. IEEE SENSORS JOURNAL, 18(21), 8893-8901 [10.1109/JSEN.2018.2867208].
Design and Experimentation of a Batteryless On-Skin RFID Graphene-Oxide Sensor for the Monitoring and Discrimination of Breath Anomalies
Caccami, M. C.;Occhiuzzi, C.;Di Natale, C.;Marrocco, G.
2018-01-01
Abstract
Real-time and comfortable monitoring of the human breathing could allow identifying anomalies in the rhythm and waveform to be correlated with several pathologic disorders of respiratory and cardiovascular systems. A wireless sensor based on a flexible Kapton substrate, suitable to be stuck over the face skin like a plaster and provided with a graphene-oxide (GO) electrode, is here proposed for application to the monitoring of the moisture emitted during inhalations and exhalations. The GO-based electrode increases its dc resistance when exposed to humidity with a sensitivity of 60Ω/RH. The device is compatible with the radiofrequency identification (RFID) standard in the UHF band. When used in battery-less mode, it can be read up to 60 cm. The RFID sensor has been successfully experimented in a measurement campaign involving 10 volunteers asked to reproduce a set of predefined normal and pathological breaths. The resulting resistance traces permit to well clusterize the breath patterns with respect to the respiration rate (extracted by a fast Fourier transform) and to the average peak variation of the sensor's resistance with an accuracy close to 90%.File | Dimensione | Formato | |
---|---|---|---|
17-Graphene.pdf
solo utenti autorizzati
Tipologia:
Versione Editoriale (PDF)
Licenza:
Copyright dell'editore
Dimensione
2.75 MB
Formato
Adobe PDF
|
2.75 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.