Advanced linear accelerator design may use Optical Transition Radiation (OTR) screens to measure beam spot size; for instance, such screens are foreseen in plasma based accelerators (EuPRAXIA@SPARC_LAB) or Compton machines (Gamma Beam Source@ELI-NP). Optical Transition Radiation angular distribution strongly depends on beam energy. Since OTR screens are typically placed in several positions along the Linac to monitor the beam envelope, one may perform a distributed energy measurement along the machine. Furthermore, a single shot energy measurement can be useful in plasma accelerators to measure shot to shot energy variations after the plasma interaction. Preliminary measurements of OTR angular distribution of about 100 MeV electrons have been performed at the SPARC_LAB facility. In this paper, we discuss the sensitivity of this measurement to beam divergence and others parameters, as well as the resolution required and the needed upgrades of conventional OTR diagnostics, using as an example the data collected at SPARC_LAB

Marongiu, M., Castellano, M., Chiadroni, E., Cianchi, A., Franzini, G., Giribono, A., et al. (2018). Energy measurements by means of transition radiation in novel Linacs. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 909, 355-358 [10.1016/j.nima.2018.02.093].

Energy measurements by means of transition radiation in novel Linacs

Cianchi A.;
2018-01-01

Abstract

Advanced linear accelerator design may use Optical Transition Radiation (OTR) screens to measure beam spot size; for instance, such screens are foreseen in plasma based accelerators (EuPRAXIA@SPARC_LAB) or Compton machines (Gamma Beam Source@ELI-NP). Optical Transition Radiation angular distribution strongly depends on beam energy. Since OTR screens are typically placed in several positions along the Linac to monitor the beam envelope, one may perform a distributed energy measurement along the machine. Furthermore, a single shot energy measurement can be useful in plasma accelerators to measure shot to shot energy variations after the plasma interaction. Preliminary measurements of OTR angular distribution of about 100 MeV electrons have been performed at the SPARC_LAB facility. In this paper, we discuss the sensitivity of this measurement to beam divergence and others parameters, as well as the resolution required and the needed upgrades of conventional OTR diagnostics, using as an example the data collected at SPARC_LAB
2018
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore FIS/07 - FISICA APPLICATA (A BENI CULTURALI, AMBIENTALI, BIOLOGIA E MEDICINA)
Settore FIS/01 - FISICA SPERIMENTALE
English
Con Impact Factor ISI
Compton gamma source; compact accelerator; instrumentation; plasma acceleration
Marongiu, M., Castellano, M., Chiadroni, E., Cianchi, A., Franzini, G., Giribono, A., et al. (2018). Energy measurements by means of transition radiation in novel Linacs. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT, 909, 355-358 [10.1016/j.nima.2018.02.093].
Marongiu, M; Castellano, M; Chiadroni, E; Cianchi, A; Franzini, G; Giribono, A; Mostacci, A; Palumbo, L; Shpakov, V; Stella, A; Variola, A
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
2018.Marongiu.NIMA.pdf

solo utenti autorizzati

Licenza: Copyright dell'editore
Dimensione 439.62 kB
Formato Adobe PDF
439.62 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/207153
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact