Background/Objectives:Bioelectrical impedance vector analysis (BIVA) is increasingly used in clinical research to assess soft tissue hydration. It is known that physical characteristics of electrodes, such as low intrinsic impedance, low electrode/skin contact impedance and type of gel, affect the reliability of noninvasive bioimpedance assessments. The aim of this study was to determine the effect of intrinsic impedance of electrode on the bioimpedance vector displacement in RXc graph.Subjects/Methods:The intrinsic impedance is measured in nine pregelled disposable Ag/AgCl electrodes usually used for bioimpedance measures. The BIVA method is performed on 35 healthy volunteers using a 50 kHz phase-sensitive bioimpedance analyzer (BIA 101 Anniversary) with the lowest intrinsic impedance electrode and highest. The individual bioimpedance vector is plotted on the bivariate normal interval of reference population. The differences in the mean bioimpedance vectors obtained with each electrode are plotted, with their 95% confidence ellipses, on the dRXc graph. The paired one-sample Hotelling's T 2 -test is used to compare the differences of the mean bioimpedance vectors.Results:We found large variability in intrinsic resistance (11-665 Ω) and reactance (0.25-2.5 Ω) values of the electrodes analyzed and significant displacement (P<0.05) of bioimpedance vector positions in healthy adults according to the paired one-sample Hotelling's T 2 -test.Conclusions:A robust study of all physical characteristics of commercial Ag/AgCl electrodes is necessary to reach consensus on pregelled Ag/AgCl electrodes valid for bioimpedance measurement. This information will enable BIVA users to avoid systemic errors when performing BIVA assessments, specifically when these measurements are used for clinical interpretations.

Nescolarde, L., Lukaski, H., De Lorenzo, A., De-Mateo-Silleras, B., Redondo-Del-Río, M.p., Camina-Martín, M.a. (2016). Different displacement of bioimpedance vector due to Ag/AgCl electrode effect. EUROPEAN JOURNAL OF CLINICAL NUTRITION, 70(12), 1401-1407 [10.1038/ejcn.2016.121].

Different displacement of bioimpedance vector due to Ag/AgCl electrode effect

De Lorenzo, A.;
2016-01-01

Abstract

Background/Objectives:Bioelectrical impedance vector analysis (BIVA) is increasingly used in clinical research to assess soft tissue hydration. It is known that physical characteristics of electrodes, such as low intrinsic impedance, low electrode/skin contact impedance and type of gel, affect the reliability of noninvasive bioimpedance assessments. The aim of this study was to determine the effect of intrinsic impedance of electrode on the bioimpedance vector displacement in RXc graph.Subjects/Methods:The intrinsic impedance is measured in nine pregelled disposable Ag/AgCl electrodes usually used for bioimpedance measures. The BIVA method is performed on 35 healthy volunteers using a 50 kHz phase-sensitive bioimpedance analyzer (BIA 101 Anniversary) with the lowest intrinsic impedance electrode and highest. The individual bioimpedance vector is plotted on the bivariate normal interval of reference population. The differences in the mean bioimpedance vectors obtained with each electrode are plotted, with their 95% confidence ellipses, on the dRXc graph. The paired one-sample Hotelling's T 2 -test is used to compare the differences of the mean bioimpedance vectors.Results:We found large variability in intrinsic resistance (11-665 Ω) and reactance (0.25-2.5 Ω) values of the electrodes analyzed and significant displacement (P<0.05) of bioimpedance vector positions in healthy adults according to the paired one-sample Hotelling's T 2 -test.Conclusions:A robust study of all physical characteristics of commercial Ag/AgCl electrodes is necessary to reach consensus on pregelled Ag/AgCl electrodes valid for bioimpedance measurement. This information will enable BIVA users to avoid systemic errors when performing BIVA assessments, specifically when these measurements are used for clinical interpretations.
2016
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MED/49 - SCIENZE TECNICHE DIETETICHE APPLICATE
English
Con Impact Factor ISI
Adult; Body Composition; Body Water; Dehydration; Female; Gels; Healthy Volunteers; Humans; Male; Middle Aged; Silver; Silver Compounds; Electric Impedance; Electrodes; Medicine (miscellaneous); Nutrition and Dietetics
http://www.nature.com/ejcn/index.html
Nescolarde, L., Lukaski, H., De Lorenzo, A., De-Mateo-Silleras, B., Redondo-Del-Río, M.p., Camina-Martín, M.a. (2016). Different displacement of bioimpedance vector due to Ag/AgCl electrode effect. EUROPEAN JOURNAL OF CLINICAL NUTRITION, 70(12), 1401-1407 [10.1038/ejcn.2016.121].
Nescolarde, L; Lukaski, H; De Lorenzo, A; De-Mateo-Silleras, B; Redondo-Del-Río, Mp; Camina-Martín, Ma
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/203722
Citazioni
  • ???jsp.display-item.citation.pmc??? 16
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 33
social impact