Microfluidic impedance cytometry offers a simple non-invasive method for single-cell analysis. Coplanar electrode chips are especially attractive due to ease of fabrication, yielding miniaturized, reproducible, and ultimately low-cost devices. However, their accuracy is challenged by the dependence of the measured signal on particle trajectory within the interrogation volume, that manifests itself as an error in the estimated particle size, unless any kind of focusing system is used. In this paper, we present an original five-electrode coplanar chip enabling accurate particle sizing without the need for focusing. The chip layout is designed to provide a peculiar signal shape from which a new metric correlating with particle trajectory can be extracted. This metric is exploited to correct the estimated size of polystyrene beads of 5.2, 6 and 7 μm nominal diameter, reaching coefficient of variations lower than the manufacturers' quoted values. The potential impact of the proposed device in the field of life sciences is demonstrated with an application to Saccharomyces cerevisiae yeast.

De Ninno, A., Errico, V., Bertani, F., Businaro, L., Bisegna, P., Caselli, F. (2017). Coplanar electrode microfluidic chip enabling accurate sheathless impedance cytometry. LAB ON A CHIP, 17(6), 1158-1166 [10.1039/c6lc01516f].

Coplanar electrode microfluidic chip enabling accurate sheathless impedance cytometry

Bisegna, P
;
Caselli F
2017-01-01

Abstract

Microfluidic impedance cytometry offers a simple non-invasive method for single-cell analysis. Coplanar electrode chips are especially attractive due to ease of fabrication, yielding miniaturized, reproducible, and ultimately low-cost devices. However, their accuracy is challenged by the dependence of the measured signal on particle trajectory within the interrogation volume, that manifests itself as an error in the estimated particle size, unless any kind of focusing system is used. In this paper, we present an original five-electrode coplanar chip enabling accurate particle sizing without the need for focusing. The chip layout is designed to provide a peculiar signal shape from which a new metric correlating with particle trajectory can be extracted. This metric is exploited to correct the estimated size of polystyrene beads of 5.2, 6 and 7 μm nominal diameter, reaching coefficient of variations lower than the manufacturers' quoted values. The potential impact of the proposed device in the field of life sciences is demonstrated with an application to Saccharomyces cerevisiae yeast.
2017
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore ING-IND/34 - BIOINGEGNERIA INDUSTRIALE
English
Con Impact Factor ISI
De Ninno, A., Errico, V., Bertani, F., Businaro, L., Bisegna, P., Caselli, F. (2017). Coplanar electrode microfluidic chip enabling accurate sheathless impedance cytometry. LAB ON A CHIP, 17(6), 1158-1166 [10.1039/c6lc01516f].
De Ninno, A; Errico, V; Bertani, F; Businaro, L; Bisegna, P; Caselli, F
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
DeNinno_Caselli_LOC_2017.pdf

accesso aperto

Licenza: Creative commons
Dimensione 3.87 MB
Formato Adobe PDF
3.87 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/200772
Citazioni
  • ???jsp.display-item.citation.pmc??? 16
  • Scopus 72
  • ???jsp.display-item.citation.isi??? 62
social impact