Using Goldmann applanation tonometry (GAT) as a gold standard, we evaluated the accuracy of Nidek NT-4000 pneumotonometry (NPT) in adults without corneal disease. Bland and Altman analysis of serial intra-ocular pressures (IOPs) measured with NPT and GAT in 10 healthy subjects revealed that the repeatability coefficients for the two methods were similar. NPT, GAT and ultrasonic pachymetry were then performed in 100 patients. Bland and Altman analysis showed that NPT yielded significantly higher readings than GAT [mean biases for right and left eye measurements were 1.37 mmHg (95% limits of agreement: -3.02-5.76) and 1.17 mmHg (95% limits of agreement: -2.76-5.11) respectively] and was more affected by corneal thickness variations. For detection of IOPs > or =21 mmHg, NPT displayed very high sensitivity (0.90) and good specificity (0.95). NPT may be useful in screening and clinical settings but borderline-high IOP readings should be confirmed with GAT.

Regine, F., Scuderi, G., Cesareo, M., Ricci, F., Cedrone, C., Nucci, C. (2006). Validity and limitations of the Nidek NT-4000 non-contact tonometer: a clinical study. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 26(1), 33-39 [10.1111/j.1475-1313.2005.00341.x].

Validity and limitations of the Nidek NT-4000 non-contact tonometer: a clinical study

CESAREO, MASSIMO;RICCI, FEDERICO;CEDRONE, CLAUDIO;NUCCI, CARLO
2006-01-01

Abstract

Using Goldmann applanation tonometry (GAT) as a gold standard, we evaluated the accuracy of Nidek NT-4000 pneumotonometry (NPT) in adults without corneal disease. Bland and Altman analysis of serial intra-ocular pressures (IOPs) measured with NPT and GAT in 10 healthy subjects revealed that the repeatability coefficients for the two methods were similar. NPT, GAT and ultrasonic pachymetry were then performed in 100 patients. Bland and Altman analysis showed that NPT yielded significantly higher readings than GAT [mean biases for right and left eye measurements were 1.37 mmHg (95% limits of agreement: -3.02-5.76) and 1.17 mmHg (95% limits of agreement: -2.76-5.11) respectively] and was more affected by corneal thickness variations. For detection of IOPs > or =21 mmHg, NPT displayed very high sensitivity (0.90) and good specificity (0.95). NPT may be useful in screening and clinical settings but borderline-high IOP readings should be confirmed with GAT.
gen-2006
Pubblicato
Rilevanza internazionale
Articolo
Sì, ma tipo non specificato
Settore MED/30 - MALATTIE APPARATO VISIVO
English
Con Impact Factor ISI
Sensitivity and specificity; aged, 80 and over; male; middle aged; female; intraocular pressure; corneal topography; humans; tonometry, ocular; aged; biometry; adult; reproducibility of results; cornea
Regine, F., Scuderi, G., Cesareo, M., Ricci, F., Cedrone, C., Nucci, C. (2006). Validity and limitations of the Nidek NT-4000 non-contact tonometer: a clinical study. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 26(1), 33-39 [10.1111/j.1475-1313.2005.00341.x].
Regine, F; Scuderi, G; Cesareo, M; Ricci, F; Cedrone, C; Nucci, C
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/19048
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 27
  • ???jsp.display-item.citation.isi??? 20
social impact