When films of zinc 5-(4-carboxyphenyl),10,15,20-triphenyl porphyrin (ZnTPP) are exposed to waterborne amine in pH- neutral or alkaline media, both Q- band and Soret band respond with a change of absorbance due to the donation of amine ‘lone pair’ electrons to the metalloprophyrin π orbital. However, this is difficult to reveal with a conventional spectrometer even under high amine concentration. We therefore introduce optical fibres coated with ZnTPP into a bespoke ‘light balance’ evanescent wave absorbance meter [doi:10.1016/j.snb.2016.05.065]. The light balance makes absorbance changes clearly visible under only 5 μM aqueous amine, making PVC membranes redundant. We find sensitivity is higher, and limit- of- detection lower, in the Soret band rather than the Q- band, reflecting the stronger Soret band absorbance. Also, we find that sensitivity is higher, and limit- of- detection approximately two times lower, when rough rather than smooth fibres are used. We believe the rough fibre surface leads to enhanced evanescence, and therefore better overlap of the wave propagating in the fibre with the ZnTPP fibre cladding. We find a limit of detection to waterborne amines below 1 μM, which compares well to other sensors for waterborne amines [Korent, S.M. et.al. Anal. Bioanal. Chem. 387 (2007) 2863–2870; Algarni, S. A. et.al. Talanta 153 (2016) 107–110]. We therefore recommend ‘rough guide’ evanescent wave optrodes, in combination with sensitive ‘light balance’ detector, to succeed membrane- embedding of colorimetric sensitisers such as metalloporphyrines. © 2016 Elsevier B.V.

Tuwei, A., Williams, N., Mulla, M., DI NATALE, C., Paolesse, R., Grell, M. (2017). ‘Rough guide’ evanescent wave optrode for colorimetric metalloporphyrine sensors. TALANTA, 164, 228-232 [10.1016/j.talanta.2016.11.057].

‘Rough guide’ evanescent wave optrode for colorimetric metalloporphyrine sensors

DI NATALE, CORRADO;PAOLESSE, ROBERTO;
2017-01-01

Abstract

When films of zinc 5-(4-carboxyphenyl),10,15,20-triphenyl porphyrin (ZnTPP) are exposed to waterborne amine in pH- neutral or alkaline media, both Q- band and Soret band respond with a change of absorbance due to the donation of amine ‘lone pair’ electrons to the metalloprophyrin π orbital. However, this is difficult to reveal with a conventional spectrometer even under high amine concentration. We therefore introduce optical fibres coated with ZnTPP into a bespoke ‘light balance’ evanescent wave absorbance meter [doi:10.1016/j.snb.2016.05.065]. The light balance makes absorbance changes clearly visible under only 5 μM aqueous amine, making PVC membranes redundant. We find sensitivity is higher, and limit- of- detection lower, in the Soret band rather than the Q- band, reflecting the stronger Soret band absorbance. Also, we find that sensitivity is higher, and limit- of- detection approximately two times lower, when rough rather than smooth fibres are used. We believe the rough fibre surface leads to enhanced evanescence, and therefore better overlap of the wave propagating in the fibre with the ZnTPP fibre cladding. We find a limit of detection to waterborne amines below 1 μM, which compares well to other sensors for waterborne amines [Korent, S.M. et.al. Anal. Bioanal. Chem. 387 (2007) 2863–2870; Algarni, S. A. et.al. Talanta 153 (2016) 107–110]. We therefore recommend ‘rough guide’ evanescent wave optrodes, in combination with sensitive ‘light balance’ detector, to succeed membrane- embedding of colorimetric sensitisers such as metalloporphyrines. © 2016 Elsevier B.V.
2017
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore CHIM/07 - FONDAMENTI CHIMICI DELLE TECNOLOGIE
Settore ING-INF/01 - ELETTRONICA
English
Con Impact Factor ISI
Alkalinity; Amines; Colorimetry; Electromagnetic wave reflection; Metals; Optical fibers; Polyvinyl chlorides; Porphyrins; Zinc compounds, Absorbance change; Alkaline media; Evanescent wave; Fibre surfaces; Limit of detection; Lock-in; Metalloporphyrins; Optrode, Fibers; Amine; Evanescent wave; Lock-in; Metalloporphyrin; Optrode
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85000788566&doi=10.1016/j.talanta.2016.11.057&partnerID=40&md5=e3780d4d89be53197e60f292bae68ec6
Tuwei, A., Williams, N., Mulla, M., DI NATALE, C., Paolesse, R., Grell, M. (2017). ‘Rough guide’ evanescent wave optrode for colorimetric metalloporphyrine sensors. TALANTA, 164, 228-232 [10.1016/j.talanta.2016.11.057].
Tuwei, A; Williams, N; Mulla, M; DI NATALE, C; Paolesse, R; Grell, M
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0039914016309377-main.pdf

solo utenti autorizzati

Licenza: Copyright dell'editore
Dimensione 556.36 kB
Formato Adobe PDF
556.36 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/175359
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact