The aim of this study was to determine the effect of thermocycling and the use of an electronically assisted application technique on the microtensile bond strength and nanoleakage of bonded interfaces created using one-step self-etch adhesives. Composite build-ups were bonded coronally to sectioned human molars using XENO III or Clearfil S3Bond. Adhesives were applied following the manufacturers' instructions (control) or with the aid of an electrical application device (ElectroBond). Teeth were sectioned into non-trimmed bonded beams for microtensile testing. Half of the specimens were subjected to 20,000 thermocycles, and the controls were not thermocycled. All specimens were tested to failure and peak stress was calculated. Additional specimens were prepared for nanoleakage analysis using transmission electron microscopy (TEM). The immediate bond strength of both adhesives increased as a result of using the ElectroBond device (XENO III 38.9 ± 8.1 MPa; Clearfil S3Bond 46.2 ± 9.9 MPa) compared with no use of the device (XENO III 26.7 ± 7.8 MPa; Clearfil S3Bond 38.9 ± 8.1 MPa). Thermocycling significantly decreased the bond strength of XENO III (27.1 ± 7.9 MPa with the use of ElectroBond; 20.7 ± 9.2 MPa without the use of ElectroBond); however, thermocycling did not affect the Clearfil S 3Bond strength (47.2 ± 8.6 MPa with the use of ElectroBond; 33.6 ± 8.3 MPa without the use of ElectroBond). Reduced nanoleakage was found for both resins as a result of the use of the ElectroBond device, with or without thermocycling. Application of one-step, self-etch adhesives with the ElectroBond device significantly increased microtensile bond strength and reduced nanoleakage, but the effect of thermocycling was found to be brand-dependent. © 2008 Eur J Oral Sci.

Visintini, E., Mazzoni, A., Vita, F., Pasquantonio, G., Cadenaro, M., Di Lenarda, R., et al. (2008). Effects of thermocycling and use of ElectroBond on microtensile strength and nanoleakage using commercial one-step self-etch adhesives. EUROPEAN JOURNAL OF ORAL SCIENCES, 116(6), 564-570 [10.1111/j.1600-0722.2008.00576.x].

Effects of thermocycling and use of ElectroBond on microtensile strength and nanoleakage using commercial one-step self-etch adhesives

PASQUANTONIO, GUIDO;
2008-01-01

Abstract

The aim of this study was to determine the effect of thermocycling and the use of an electronically assisted application technique on the microtensile bond strength and nanoleakage of bonded interfaces created using one-step self-etch adhesives. Composite build-ups were bonded coronally to sectioned human molars using XENO III or Clearfil S3Bond. Adhesives were applied following the manufacturers' instructions (control) or with the aid of an electrical application device (ElectroBond). Teeth were sectioned into non-trimmed bonded beams for microtensile testing. Half of the specimens were subjected to 20,000 thermocycles, and the controls were not thermocycled. All specimens were tested to failure and peak stress was calculated. Additional specimens were prepared for nanoleakage analysis using transmission electron microscopy (TEM). The immediate bond strength of both adhesives increased as a result of using the ElectroBond device (XENO III 38.9 ± 8.1 MPa; Clearfil S3Bond 46.2 ± 9.9 MPa) compared with no use of the device (XENO III 26.7 ± 7.8 MPa; Clearfil S3Bond 38.9 ± 8.1 MPa). Thermocycling significantly decreased the bond strength of XENO III (27.1 ± 7.9 MPa with the use of ElectroBond; 20.7 ± 9.2 MPa without the use of ElectroBond); however, thermocycling did not affect the Clearfil S 3Bond strength (47.2 ± 8.6 MPa with the use of ElectroBond; 33.6 ± 8.3 MPa without the use of ElectroBond). Reduced nanoleakage was found for both resins as a result of the use of the ElectroBond device, with or without thermocycling. Application of one-step, self-etch adhesives with the ElectroBond device significantly increased microtensile bond strength and reduced nanoleakage, but the effect of thermocycling was found to be brand-dependent. © 2008 Eur J Oral Sci.
2008
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MED/28 - MALATTIE ODONTOSTOMATOLOGICHE
English
Con Impact Factor ISI
Adhesion; Dentin; Electricity; Microtensile; Thermocycling; Acid Etching, Dental; Dental Bonding; Dental Leakage; Dental Stress Analysis; Electric Conductivity; Humans; Iontophoresis; Molar, Third; Random Allocation; Statistics, Nonparametric; Temperature; Dentin-Bonding Agents; Resin Cements; Tensile Strength; Dentistry (all)
Visintini, E., Mazzoni, A., Vita, F., Pasquantonio, G., Cadenaro, M., Di Lenarda, R., et al. (2008). Effects of thermocycling and use of ElectroBond on microtensile strength and nanoleakage using commercial one-step self-etch adhesives. EUROPEAN JOURNAL OF ORAL SCIENCES, 116(6), 564-570 [10.1111/j.1600-0722.2008.00576.x].
Visintini, E; Mazzoni, A; Vita, F; Pasquantonio, G; Cadenaro, M; Di Lenarda, R; Breschi, L
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
Eur_J_Oral_Sci_2008_Visintini.pdf

solo utenti autorizzati

Licenza: Copyright dell'editore
Dimensione 357.06 kB
Formato Adobe PDF
357.06 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/169347
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 21
social impact