OBJECTIVE: Historically, a set of 5 cardiovascular autonomic reflex tests (CARTs) was considered to be the gold standard in the assessment of cardiovascular autonomic neuropathy (CAN). However, measuring diastolic blood pressure (BP) response to sustained handgrip is omitted in recent guidelines. We aimed to assess the association between the handgrip and the other 4 tests as well as to identify determinants of the handgrip test results in diabetic patients. PATIENTS AND METHODS: 353 patients with diabetes (DM) were recruited (age: 60.2±7.4 years; female: 57.2%; BMI: 29.3±2.1 kg/m2; DM duration: 15.6±9.9 years; HbA1c: 7.8±1.4% (66 mmol/mol); with type 1 DM: 18.1%). CAN was assessed by 5 CARTs: the deep breathing test, Valsalva ratio, 30/15 ratio, handgrip and orthostatic hypotension test. RESULTS: Sensitivity and specificity of the handgrip test in the diagnosis of definite CAN were 24.6% (95%CI 17.7-33.1%) and 79.4% (95%CI 73.3-84.4%), respectively. Results of the handgrip test did not show any association with those of the deep-breathing test (γ=0.004, p=0.563), 30/15 ratio (γ=0.282, p=0.357), Valsalva ratio (γ=-0.058, p=0.436) and orthostatic hypotension (γ=-0.026, p=0.833). Handgrip test abnormality showed an independent association with higher initial diastolic BP (OR 1.05, p=0.0009) and an independent inverse association with the presence of hypertension (OR=0.42, p=0.006). CONCLUSIONS: Our data confirm that the handgrip test should no longer be part of the cardiovascular autonomic testing being highly dependent on hypertensive status and baseline diastolic BP. Exaggerated exercise pressor response is proposed as putative mechanism for the inverse association between abnormal results of the handgrip test and hypertension. Adequate CARTs important to allow their use in clinical trials and for the prevention of DM-associated complications by initiating early treatment.

Körei, A., Kempler, M., Istenes, I., Vági, O., Putz, Z., Horváth, V., et al. (2017). Why not to use the handgrip test in the assessment of cardiovascular autonomic neuropathy among patients with diabetes mellitus?. CURRENT VASCULAR PHARMACOLOGY, 15(1), 66-73.

Why not to use the handgrip test in the assessment of cardiovascular autonomic neuropathy among patients with diabetes mellitus?

SPALLONE, VINCENZA;
2017-01-01

Abstract

OBJECTIVE: Historically, a set of 5 cardiovascular autonomic reflex tests (CARTs) was considered to be the gold standard in the assessment of cardiovascular autonomic neuropathy (CAN). However, measuring diastolic blood pressure (BP) response to sustained handgrip is omitted in recent guidelines. We aimed to assess the association between the handgrip and the other 4 tests as well as to identify determinants of the handgrip test results in diabetic patients. PATIENTS AND METHODS: 353 patients with diabetes (DM) were recruited (age: 60.2±7.4 years; female: 57.2%; BMI: 29.3±2.1 kg/m2; DM duration: 15.6±9.9 years; HbA1c: 7.8±1.4% (66 mmol/mol); with type 1 DM: 18.1%). CAN was assessed by 5 CARTs: the deep breathing test, Valsalva ratio, 30/15 ratio, handgrip and orthostatic hypotension test. RESULTS: Sensitivity and specificity of the handgrip test in the diagnosis of definite CAN were 24.6% (95%CI 17.7-33.1%) and 79.4% (95%CI 73.3-84.4%), respectively. Results of the handgrip test did not show any association with those of the deep-breathing test (γ=0.004, p=0.563), 30/15 ratio (γ=0.282, p=0.357), Valsalva ratio (γ=-0.058, p=0.436) and orthostatic hypotension (γ=-0.026, p=0.833). Handgrip test abnormality showed an independent association with higher initial diastolic BP (OR 1.05, p=0.0009) and an independent inverse association with the presence of hypertension (OR=0.42, p=0.006). CONCLUSIONS: Our data confirm that the handgrip test should no longer be part of the cardiovascular autonomic testing being highly dependent on hypertensive status and baseline diastolic BP. Exaggerated exercise pressor response is proposed as putative mechanism for the inverse association between abnormal results of the handgrip test and hypertension. Adequate CARTs important to allow their use in clinical trials and for the prevention of DM-associated complications by initiating early treatment.
2017
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MED/13 - ENDOCRINOLOGIA
English
Con Impact Factor ISI
diabetes; cardiovascular autonomic neuropathy; handgrip test; hypertension
Körei, A., Kempler, M., Istenes, I., Vági, O., Putz, Z., Horváth, V., et al. (2017). Why not to use the handgrip test in the assessment of cardiovascular autonomic neuropathy among patients with diabetes mellitus?. CURRENT VASCULAR PHARMACOLOGY, 15(1), 66-73.
Körei, A; Kempler, M; Istenes, I; Vági, O; Putz, Z; Horváth, V; Keresztes, K; Lengyel, C; Tabák, A; Spallone, V; Kempler, P
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
KöreiA.SpalloneV.Curr Vasc Pharmacol2016.pdf

solo utenti autorizzati

Descrizione: Articolo dopo revisione
Licenza: Copyright dell'editore
Dimensione 132.64 kB
Formato Adobe PDF
132.64 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/166706
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 17
  • ???jsp.display-item.citation.isi??? 16
social impact