High-efficiency power-amplifier design requires numerous efforts to investigate both input and output harmonic terminations effects. A simplified theoretical approach to clarify the relevance of such terminations is presented here, and design criteria to improve efficiency for high-frequency applications are briefly discussed. An advanced active load/source–pull test-bench has been used to validate theoretical harmonic tuning techniques, characterizing an active device. The adopted optimization strategy is presented, together with measured results obtained with a medium-power 1-mm MESFET at 1 GHz. Input second harmonic impedances effects are stressed, showing a drain efficiency spread between 37%–49% for a fixed input power level, corresponding to 1-dB compression. Finally, as predicted by the presented theory, after input second harmonic tuning, further improvements are obtained, increasing fundamental output load resistive part, demonstrating an additional drain efficiency enhancement, which reaches a level of 55% at 1-dB compression.

Colantonio, P., Giannini, F., Limiti, E., Teppati, V. (2004). An approach to harmonic load– and source–pull measurements for high-efficiency PA design. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 52(1), 191-198 [10.1109/TMTT.2003.821276].

An approach to harmonic load– and source–pull measurements for high-efficiency PA design

COLANTONIO, PAOLO;GIANNINI, FRANCO;LIMITI, ERNESTO;
2004-01-01

Abstract

High-efficiency power-amplifier design requires numerous efforts to investigate both input and output harmonic terminations effects. A simplified theoretical approach to clarify the relevance of such terminations is presented here, and design criteria to improve efficiency for high-frequency applications are briefly discussed. An advanced active load/source–pull test-bench has been used to validate theoretical harmonic tuning techniques, characterizing an active device. The adopted optimization strategy is presented, together with measured results obtained with a medium-power 1-mm MESFET at 1 GHz. Input second harmonic impedances effects are stressed, showing a drain efficiency spread between 37%–49% for a fixed input power level, corresponding to 1-dB compression. Finally, as predicted by the presented theory, after input second harmonic tuning, further improvements are obtained, increasing fundamental output load resistive part, demonstrating an additional drain efficiency enhancement, which reaches a level of 55% at 1-dB compression.
gen-2004
Pubblicato
Rilevanza internazionale
Articolo
Sì, ma tipo non specificato
Settore ING-INF/01 - ELETTRONICA
English
Con Impact Factor ISI
Colantonio, P., Giannini, F., Limiti, E., Teppati, V. (2004). An approach to harmonic load– and source–pull measurements for high-efficiency PA design. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 52(1), 191-198 [10.1109/TMTT.2003.821276].
Colantonio, P; Giannini, F; Limiti, E; Teppati, V
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/15805
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 97
  • ???jsp.display-item.citation.isi??? 71
social impact