BACKGROUND: The available clinical outcome measures of disability in multiple sclerosis are not adequately responsive or sensitive. OBJECTIVE: To investigate the feasibility of inertial sensor-based gait analysis in multiple sclerosis. METHODS: A cross-sectional study of 80 multiple sclerosis patients and 50 healthy controls was performed. Lower-limb kinematics was evaluated by using a commercially available magnetic inertial measurement unit system. Mean and standard deviation of range of motion (mROM, sROM) for each joint of lower limbs were calculated in one minute walking test. A motor performance index (E) defined as the sum of sROMs was proposed. RESULTS: We established two novel observer-independent measures of disability. Hip mROM was extremely sensitive in measuring lower limb motor impairment, being correlated with muscle strength and also altered in patients without clinically detectable disability. On the other hand, E index discriminated patients according to disability, being altered only in patients with moderate and severe disability, regardless of walking speed. It was strongly correlated with fatigue and patient-perceived health status. CONCLUSIONS: Inertial sensor-based gait analysis is feasible and can detect clinical and subclinical disability in multiple sclerosis.

Motta, C., Palermo, E., Studer, V., Germanotta, M., Germani, G., Centonze, D., et al. (2016). Disability and Fatigue Can Be Objectively Measured in Multiple Sclerosis. PLOS ONE, 11(2), e0148997 [10.1371/journal.pone.0148997].

Disability and Fatigue Can Be Objectively Measured in Multiple Sclerosis

CENTONZE, DIEGO;ROSSI, SILVIA;
2016-02-10

Abstract

BACKGROUND: The available clinical outcome measures of disability in multiple sclerosis are not adequately responsive or sensitive. OBJECTIVE: To investigate the feasibility of inertial sensor-based gait analysis in multiple sclerosis. METHODS: A cross-sectional study of 80 multiple sclerosis patients and 50 healthy controls was performed. Lower-limb kinematics was evaluated by using a commercially available magnetic inertial measurement unit system. Mean and standard deviation of range of motion (mROM, sROM) for each joint of lower limbs were calculated in one minute walking test. A motor performance index (E) defined as the sum of sROMs was proposed. RESULTS: We established two novel observer-independent measures of disability. Hip mROM was extremely sensitive in measuring lower limb motor impairment, being correlated with muscle strength and also altered in patients without clinically detectable disability. On the other hand, E index discriminated patients according to disability, being altered only in patients with moderate and severe disability, regardless of walking speed. It was strongly correlated with fatigue and patient-perceived health status. CONCLUSIONS: Inertial sensor-based gait analysis is feasible and can detect clinical and subclinical disability in multiple sclerosis.
10-feb-2016
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore MED/26 - NEUROLOGIA
English
Con Impact Factor ISI
Part of this work was supported by a grant from the Italian Institute of Technology (IIT) – Project Seed (“ITINERE—Interactive Technology: an Instrumented Novel Exoskeleton for Rehabilitation” 2009).
Motta, C., Palermo, E., Studer, V., Germanotta, M., Germani, G., Centonze, D., et al. (2016). Disability and Fatigue Can Be Objectively Measured in Multiple Sclerosis. PLOS ONE, 11(2), e0148997 [10.1371/journal.pone.0148997].
Motta, C; Palermo, E; Studer, V; Germanotta, M; Germani, G; Centonze, D; Cappa, P; Rossi, S; Rossi, S
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/141151
Citazioni
  • ???jsp.display-item.citation.pmc??? 14
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 25
social impact