Aim. The purpose of this study was to evaluate morphological and biomechanical characteristics of a commercial mini-implant. Methods. Orthodontic low head mini implants, in the two available sizes of 1,5 and 2 mm, have been used. The SEM (electronic scanning microscope) evaluation has been tested on 3 groups each one composed of 4 samples, observed in numerous enlargements and in the three dimensions of the space. The groups was composed of new mini implants, undamaged mini implants observed after their clinical use and mini implants broken at the moment of their insertion or removal after their therapeutical use. Results. The SEM analysis of unused mini implants has shown how the diameter reduction of the neck represents the area of greater weakness; such parameter is very important in determining screw resistance to fracture. In fact the fracture observed in vivo always happened to this degree. Some micro carvings and cracks were shown on the surface, these irregularities could facilitate or promote the enlargement of the cracking itself. Conclusion. From the results obtained it is clear that the steel is adequate for permanence in the oral cavity, and moreover the material itself is adapted to bear the pressure put on it during therapy. However, it remains advisable to make certain changes to better the surface and geometry of the miniscrews.

Casaglia, A., Dominici, F., Pachi', F., Turlà, R., Cerroni, L. (2010). Morphological observations and fractological considerations on orthodontics miniscrews. MINERVA STOMATOLOGICA, 59(9), 465-476.

Morphological observations and fractological considerations on orthodontics miniscrews

PACHI', FRANCESCO;CERRONI, LOREDANA
2010-01-01

Abstract

Aim. The purpose of this study was to evaluate morphological and biomechanical characteristics of a commercial mini-implant. Methods. Orthodontic low head mini implants, in the two available sizes of 1,5 and 2 mm, have been used. The SEM (electronic scanning microscope) evaluation has been tested on 3 groups each one composed of 4 samples, observed in numerous enlargements and in the three dimensions of the space. The groups was composed of new mini implants, undamaged mini implants observed after their clinical use and mini implants broken at the moment of their insertion or removal after their therapeutical use. Results. The SEM analysis of unused mini implants has shown how the diameter reduction of the neck represents the area of greater weakness; such parameter is very important in determining screw resistance to fracture. In fact the fracture observed in vivo always happened to this degree. Some micro carvings and cracks were shown on the surface, these irregularities could facilitate or promote the enlargement of the cracking itself. Conclusion. From the results obtained it is clear that the steel is adequate for permanence in the oral cavity, and moreover the material itself is adapted to bear the pressure put on it during therapy. However, it remains advisable to make certain changes to better the surface and geometry of the miniscrews.
2010
Pubblicato
Rilevanza nazionale
Articolo
Sì, ma tipo non specificato
Settore MED/28 - MALATTIE ODONTOSTOMATOLOGICHE
English
Senza Impact Factor ISI
Casaglia, A., Dominici, F., Pachi', F., Turlà, R., Cerroni, L. (2010). Morphological observations and fractological considerations on orthodontics miniscrews. MINERVA STOMATOLOGICA, 59(9), 465-476.
Casaglia, A; Dominici, F; Pachi', F; Turlà, R; Cerroni, L
Articolo su rivista
File in questo prodotto:
File Dimensione Formato  
2010MinervaStom.pdf

solo utenti autorizzati

Licenza: Copyright dell'editore
Dimensione 4.24 MB
Formato Adobe PDF
4.24 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/13231
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? ND
social impact