Body composition assessment is a useful procedure for the study of nutritional status and water distribution. In adults, it is a predictor of morbidity and mortality, since body fatness is associated with risk factors for cardiovascular disease. Bioelectric impedance analysis (BIA) is a simple, safe, and inexpensive method for assessment of body composition both in pediatric and adult subjects. The aim of our study was to validate the impedance index, ZI (H(2)/Z, height in cm(2)/impedance), as a predictor factor of fatfree mass (FFM) and fat mass (FM) in a sample ( n=75) of normal children. Dual-energy X-ray absorptiometry (DXA) was chosen as reference method. Despite some minor bias, DXAis considerably less expensive and easier to administer in pediatric subjects than other established gold standard reference methods for assessing body composition. ZI values were highly correlated with FFM measured with DXA. The following equations were obtained from the regression analysis: (a). male subjects, FFM(DXA)=0.6375 (ZI)+5.9913, r(2)=0.897, p<0.0001; (b). female subjects, FFM(DXA)=0.7597 (ZI)+ 3.5853, r(2)=0.903, p<0.0001. These data support the notion that BIA alone can be used as a surrogate to measure FFM in a pediatric sample.

Pietrobelli, A., Andreoli, A., Cervelli, V., Carbonelli, M., Peroni, D., DE LORENZO, A. (2003). Predicting fat-free mass in children using bioimpedance analysis. ACTA DIABETOLOGICA, 40 Suppl 1, S212-5 [10.1007/s00592-003-0069-z].

Predicting fat-free mass in children using bioimpedance analysis

ANDREOLI, ANGELA;CERVELLI, VALERIO;DE LORENZO, ANTONINO
2003-10-01

Abstract

Body composition assessment is a useful procedure for the study of nutritional status and water distribution. In adults, it is a predictor of morbidity and mortality, since body fatness is associated with risk factors for cardiovascular disease. Bioelectric impedance analysis (BIA) is a simple, safe, and inexpensive method for assessment of body composition both in pediatric and adult subjects. The aim of our study was to validate the impedance index, ZI (H(2)/Z, height in cm(2)/impedance), as a predictor factor of fatfree mass (FFM) and fat mass (FM) in a sample ( n=75) of normal children. Dual-energy X-ray absorptiometry (DXA) was chosen as reference method. Despite some minor bias, DXAis considerably less expensive and easier to administer in pediatric subjects than other established gold standard reference methods for assessing body composition. ZI values were highly correlated with FFM measured with DXA. The following equations were obtained from the regression analysis: (a). male subjects, FFM(DXA)=0.6375 (ZI)+5.9913, r(2)=0.897, p<0.0001; (b). female subjects, FFM(DXA)=0.7597 (ZI)+ 3.5853, r(2)=0.903, p<0.0001. These data support the notion that BIA alone can be used as a surrogate to measure FFM in a pediatric sample.
ott-2003
Pubblicato
Rilevanza internazionale
Articolo
Sì, ma tipo non specificato
Settore MED/49 - SCIENZE TECNICHE DIETETICHE APPLICATE
English
Male; Absorptiometry, Photon; Body Mass Index; Female; Electric Impedance; Child; Adipose Tissue; Reference Values; Body Weight; Body Composition; Humans; Body Height
Pietrobelli, A., Andreoli, A., Cervelli, V., Carbonelli, M., Peroni, D., DE LORENZO, A. (2003). Predicting fat-free mass in children using bioimpedance analysis. ACTA DIABETOLOGICA, 40 Suppl 1, S212-5 [10.1007/s00592-003-0069-z].
Pietrobelli, A; Andreoli, A; Cervelli, V; Carbonelli, M; Peroni, D; DE LORENZO, A
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/12232
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 54
  • ???jsp.display-item.citation.isi??? 45
social impact