Background: Analysis of exhaled breath by biosensors discriminates between patients with asthma and healthy subjects. An electronic nose consists of a chemical sensor array for the detection of volatile organic compounds (VOCs) and an algorithm for pattern recognition. We compared the diagnostic performance of a prototype of an electronic nose with lung function tests and fractional exhaled nitric oxide (FENO) in patients with atopic asthma. Methods: A cross-sectional study was undertaken in 27 patients with intermittent and persistent mild asthma and in 24 healthy subjects. Two procedures for collecting exhaled breath were followed to study the differences between total and alveolar air. Seven patients with asthma and seven healthy subjects participated in a study with mass spectrometry (MS) fingerprinting as an independent technique for assessing between group discrimination. Classification was based on principal component analysis and a feed-forward neural network. Results: The best results were obtained when the electronic nose analysis was performed on alveolar air. Diagnostic performance for electronic nose, FENO, and lung function testing was 87.5%, 79.2%, and 70.8%, respectively. The combination of electronic nose and FENO had the highest diagnostic performance for asthma (95.8%). MS fingerprints of VOCs could discriminate between patients with asthma and healthy subjects. Conclusions: The electronic nose has a high diagnostic performance that can be increased when combined with FENO. Large studies are now required to definitively establish the diagnostic performance of the electronic nose. Whether this integrated noninvasive approach will translate into an early diagnosis of asthma has to be clarified

Montuschi, P., Santonico, M., Mondino, C., Pennazza, G., Maritini, G., Martinelli, E., et al. (2010). Diagnostic performance of an electronic nose, fractional exhaled nitric oxide, and lung function testing in asthma. CHEST, 137(4), 790-796 [10.1378/chest.09-1836].

Diagnostic performance of an electronic nose, fractional exhaled nitric oxide, and lung function testing in asthma

MARTINELLI, EUGENIO;Capuano, R;PAOLESSE, ROBERTO;DI NATALE, CORRADO;D'AMICO, ARNALDO
2010-01-01

Abstract

Background: Analysis of exhaled breath by biosensors discriminates between patients with asthma and healthy subjects. An electronic nose consists of a chemical sensor array for the detection of volatile organic compounds (VOCs) and an algorithm for pattern recognition. We compared the diagnostic performance of a prototype of an electronic nose with lung function tests and fractional exhaled nitric oxide (FENO) in patients with atopic asthma. Methods: A cross-sectional study was undertaken in 27 patients with intermittent and persistent mild asthma and in 24 healthy subjects. Two procedures for collecting exhaled breath were followed to study the differences between total and alveolar air. Seven patients with asthma and seven healthy subjects participated in a study with mass spectrometry (MS) fingerprinting as an independent technique for assessing between group discrimination. Classification was based on principal component analysis and a feed-forward neural network. Results: The best results were obtained when the electronic nose analysis was performed on alveolar air. Diagnostic performance for electronic nose, FENO, and lung function testing was 87.5%, 79.2%, and 70.8%, respectively. The combination of electronic nose and FENO had the highest diagnostic performance for asthma (95.8%). MS fingerprints of VOCs could discriminate between patients with asthma and healthy subjects. Conclusions: The electronic nose has a high diagnostic performance that can be increased when combined with FENO. Large studies are now required to definitively establish the diagnostic performance of the electronic nose. Whether this integrated noninvasive approach will translate into an early diagnosis of asthma has to be clarified
2010
Pubblicato
Rilevanza internazionale
Articolo
Esperti anonimi
Settore CHIM/07 - FONDAMENTI CHIMICI DELLE TECNOLOGIE
Settore ING-INF/01 - ELETTRONICA
English
Con Impact Factor ISI
nitric oxide, adult; allergic asthma; article; artificial neural network; clinical article; controlled study; diagnostic test; DNA fingerprinting; electronic sensor; expired air; female; gas chromatography; human; lung function; male; mass spectrometry; nose; priority journal; respiratory airflow; spirometry, Adult; Algorithms; Asthma; Biosensing Techniques; Breath Tests; Case-Control Studies; Cross-Sectional Studies; Diagnostic Tests, Routine; Exhalation; Female; Humans; Lung; Male; Mass Spectrometry; Nitric Oxide; Respiratory Function Tests; Volatile Organic Compounds
Montuschi, P., Santonico, M., Mondino, C., Pennazza, G., Maritini, G., Martinelli, E., et al. (2010). Diagnostic performance of an electronic nose, fractional exhaled nitric oxide, and lung function testing in asthma. CHEST, 137(4), 790-796 [10.1378/chest.09-1836].
Montuschi, P; Santonico, M; Mondino, C; Pennazza, G; Maritini, G; Martinelli, E; Capuano, R; Ciabattoni, G; Paolesse, R; DI NATALE, C; Barnes, P; D'Am...espandi
Articolo su rivista
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/2108/11676
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 176
  • ???jsp.display-item.citation.isi??? 164
social impact